25
Auto
Changeover
YES
Energy
Save
Heat
NO
Energy
Save
Cool
NO
AWAY
NO
ZXT
‐
120
functions
and
Parameters
summaries:
FUNCTIONS
AIR
CONDITIONER
FUNCTION
Z-WAVE COMMAND CLASS
Z-WAVE
COMMAND
COMMAND
PARAMETER
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 5
POWER ON
COMMAND_CLASS_BASIC BASIC_SET
VALUE
=
0XFF
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 0
POWER
POWER OFF
COMMAND_CLASS_BASIC BASIC_SET
VALUE
=
0X00
AUTO
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 3
COOL
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 2
FAN
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 6
HEAT
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 1
DRY
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 8
MODE
AUTO
Changeover
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 10
SETPOINT TYPE =
1,
HEAT mode
Temperature
TEMPERATURE
VALUE
SETPOINT TYPE =
2,
COOL mode
Temperature
TEMPERATURE
VALUE
SETPOINT TYPE =
8,
DRY mode
Temperature
TEMPERATURE
VALUE
SETPOINT TYPE =
10,
TEMPERATURE
SETTING
AUTO mode
Temperature
COMMAND_CLASS_THERMOSTAT
_SETPOINT
THERMOSTAT_
SETPOINT_SET
TEMPERATURE
VALUE
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v1
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 0
FAN SPEED
FAN AUTO
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 0, 2, or
4