15
IR
Learning
Mapping
Table
(Parameter
number
25)
Parameter
Value
(Location)
Thermostat
command
&
IR
setting
0
OFF
1
ON
(resume)
2
19°C
cool
3
20°C
cool
4
21°C
cool
5
22°C
cool
6
23°C
cool
7
24°C
cool
8
25°C
cool
9
26°C
cool
Default
Cool
10
27°C
cool
11
28°C
cool
12
19°C
heat
13
20°C
heat
14
21°C
heat
15
22°C
heat
Default
Heat
16
23°C
heat
17
24°C
heat
18
25°
C
heat
19
26°C
heat
20
27°C
heat
21
28°C
heat
22
Dry
mode