2
Technical Data
2.1 Units data WKF/WKF-compact 85
Series
WKF 85
WKF-com-
pact 85
Function
Heating or Cooling
System
Split-Air/Water
Heat pump manager
Smart-Control
Domestic water storage tank, enamelled
optional
Ser. 300 l
Electric booster heating / rated output
kW
optional / 9,0
Domestic hot-water heating (changeover valve)
optional
Series
Connecting oil-/ gas boiler
optional
Heating capacity min / max
kW
1,1 - 9,3
Heating capacity / compressor
frequency / COP for A12/W35
kW/Hz/COP
9,17/56/4,78
Heating capacity / compressor
frequency / COP
1)
for A7/W35
kW/Hz/COP
7,97/56/4,37
Heating capacity / compressor
frequency / COP
1)
for A2/W35
kW/Hz/COP
4,87/56/3,34
Heating capacity / compressor
frequency / COP
1)
for A-7/W35
kW/Hz/COP
4,31/54/2,77
Heating capacity / compressor
frequency / COP
1)
for A-15/W35
kW/ Hz/COP
3,42/54/2,28
Heating capacity / compressor
frequency / COP
1)
for A7/W45
kW/Hz/COP
6,74/56/3,23
Heating capacity / compressor
frequency / COP
1)
for A-7/W45
kW/Hz/COP
3,94/56/2,13
Heating capacity / compressor
frequency / COP
1)
for A7/W55
kW/Hz/COP
-
Heating capacity / compressor
frequency / COP
1)
for A-7/W55
kW/Hz/COP
-
Cooling capacity min. / max.
kW
1,6 - 7,2
Cooling capacity / compressor
frequency / EER for A35/W7
kW/Hz/EER
5,59/49/3,04
Cooling capacity / compressor
frequency / EER for A35/W18
kW/Hz/EER
7,47/49/3,86
Cooling capacity / compressor
frequency / EER for A27/W18
kW/Hz/EER
6,9/49/4,42
Service limits, heating
°C
-20 - +45
Service limits, cooling
°C
+15 - +45
Supply-temperature, heating water
°C
50
Min. Supply-temperature, cooling
°C
7