Heating capacity WKF 180 Duo at an inlet temperature 55 °C
[°C]
[k
W
]
0,0
5,0
10,0
15,0
20,0
25,0
30,0
35,0
40,0
-16
-14
-12
-10
-8
-6
-4
-2
0
2
4
6
8
10
12
14
16
18
20
A
B
C
n-max
Fig. 39: Heating capacity WKF 180 Duo at an inlet temperature 55 °C
A: Outdoor temperature
B: Heating capacity
C: Rated frequency / n-max = max. frequency
COP WKF 180 Duo at an inlet temperature 35 °C, 45 °C und 55 °C
[°C]
C
O
P
[-]
0
1
2
3
4
5
6
-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
35° C
45° C
55° C
A
D
D
D
Fig. 40: COP WKF 180 Duo at an inlet temperature 35 °C, 45 °C und 55 °C
A: Outdoor temperature
D: Inlet temperature
39