2.6 Product data WKF 120/180 Duo
Average condition
1)
Series
WKF 120 Duo
WKF 180 Duo
Energy efficiency ratio, heating 35°C/55°C
A++ / A+
A++ / A++
Energy efficiency ratio, hot water XL
A
A
Nominal heating power prated
kW
18,0
29,0
Room heating energy efficiency
h
s 35°C/55°C
%
154 / 116
151 / 125
Contribution to seasonal room heating energy effi-
ciency of the REMKO Smart Control
%
4
4
Yearly energy consumption Q
HE
35°C/55°C
4)
9282 / 11218
15524 / 17 719
Hot water preparation energy efficiency
h
wH
%
102
107
Sound power level L
WA
(outdoor module)
dB(A)
67,9
67,9
Sound power level L
WA
(indoor module)
dB(A)
-
-
Warmer condition
2)
Series
WKF 120 Duo
WKF 180 Duo
Energy efficiency ratio, heating 35°C/55°C
A+++ / A++
A+++ / A+++
Energy efficiency ratio, hot water XL
A
A
Nominal heating power prated
kW
17,0
25,0
Room heating energy efficiency
h
s 35°C/55°C
%
184 / 134
194 / 152
Yearly energy consumption Q
HE
35°C/55°C
4)
4897 / 4953
6981 / 7338
Colder condition
3)
Series
WKF 120 Duo
WKF 180 Duo
Energy efficiency ratio, heating 35°C/55°C
A+ / A+
A+ / A+
Energy efficiency ratio, hot water XL
A
A
Nominal heating power prated
kW
24,0
38,0
Room heating energy efficiency
h
s 35°C/55°C
%
137 / 103
125 / 103
Yearly energy consumption Q
HE
35°C/55°C
4)
16918 / 19617
29632 / 35842
1)
Average condition = moderate temperature periods
2)
Warmer condition = warm temperature periods
3)
Colder condition = cold temperature periods
4)
The specified value is based on results from standard testing.
The actual consumption depends on the use and location of the unit