Technical Data

Device type

MKT 250

MKT 250 

Nominal cooling capacity 

1)

kW

2,62

Energy efficiency class, cooling

A

Energy efficiency factor EER 

1)

2,65

Application range (room air volume), approx.

80

Temperature setting range

°C

+16 up to +32

Temperature operating limits

°C /%r.F.

+16 bis +35 / +35 bis +85

Refrigerant

R 410A

Operating pressure max., cooling circle

kPa

1900 / 2800

Refrigerant quantity

kg

0,65

Circulation air volume flow rate

m³/h

240 / 270 / 320

Sound pressure level 

2)

dB(A)

45 / 50 / 53

Voltage supply

V/Hz

230 / 1~ / 50

Type of protection

IP

20

Power consumption 

1)

kW

0,99

Current consumption 

1)

A

4,56

Electrical starting current

A

21

Air outlet hose, diameter

mm/mm

1200 / 125

Diemsions height/width/depth

mm

700

Weight

kg

32,0

Color

white

silver

Serial no.

920...

921...

Ref.no.

1612250

1612251

1) Room temperature dry-bulb DK 35°C / wet-bulb VK 24°C 
2) Distance 1 m

Summary of Contents for MKT 250

Page 1: ...dify Mode Fan Mode Timer Functional Principle of the Cooling Process Maintenance and Care Cleaning the Filter Draining the Condensate Trouble Shooting Taking the Device Out of Service Warranty Environ...

Page 2: ...ains supply line Protect all electrical lines of the device from damage even from animals Select the extension lines of the mains supply line depending on the connected load of the device the line len...

Page 3: ...that the cooling effect can be maintained Observe the following notices Plug the air outlet hose in cluded in delivery onto the air outlet on the rear panel of the device Lock both catches on the air...

Page 4: ...splay 7 13 Green Set Temp LED 14 C F toggle button only on the remote control Operation The device is operated comfortably using the control panel on the device or the in frared remote control Keys wi...

Page 5: ...is pressed the display switches from the room temperature to the set tempera ture LED 13 lights up and shows the desired temperature for 15 seconds 7 Set the desired room temperature using the Timer T...

Page 6: ...ondensate Draining the condensate The condensate evaporates during operation and is then conducted outside with the exhaust air via the air outlet hose In case of extreme humidity the device collects...

Page 7: ...e and pull the mains plug 2 Place a flat tray under the condensate drain spout and remove the plug Fig 17 3 After the condensate has drained reinsert the plug firmly The device is not cooling properly...

Page 8: ...sign sub ject to alteration Control panel Evaporator fan Condenser Red Orange Yellow White Red Red Red Blue Blue Blue Blue Condenser Condenser Compressor Evaporator fan Reservoir motor Mains plug Whit...

Page 9: ...to the wall bushing To prevent cold bridges insulate the telescopic pipe with suitable insulating material Wall the telescopic pipe into the core hole in such a way that it is flush to both sides of t...

Page 10: ...O MKT 11 Fig 20 Device diagram of the MKT 250 Technical dimensions and design subject to alteration 28 31 29 30 17 18 25 19 20 15 24 32 22 8 10 9 5 16 7 6 21 4 13 14 11 26 27 12 23 1 2 3 33 Device Dia...

Page 11: ...824 15 Exhaust air pipe adapter 1106865 1106865 16 Condenser 1 5 F 1106866 1106866 17 Evaporator 1106894 1106894 18 Fan housing circulation air 1106822 1106822 19 Fan wheel circulation air 1106823 110...

Page 12: ...ume approx m 80 Temperature setting range C 16 up to 32 Temperature operating limits C r F 16 bis 35 35 bis 85 Refrigerant R 410A Operating pressure max cooling circle kPa 1900 2800 Refrigerant quanti...

Reviews: