background image

REMKO MKT 250

Portable Air Conditioner  

 

Operation • Technology • Spare Parts

Safety Notices

Scope of Supply

Device Structure 

Erecting the Device 
Exhaust Air Conductance

Operation

Control Panel and Remote Control 

“Mode“ Selection 

“Cool“ Mode

“Dehumidify“ Mode

 “Fan“ Mode

“Timer“

Functional Principle of the Cooling Process

Maintenance and Care

Cleaning the Filter
Draining the Condensate
Trouble Shooting

Taking the Device Out of Service

Warranty

Environment and Recycling

Technology

Electrical Wiring Diagram
Installation Instructions for the Wall Bushing
Device Diagram
Spare Part List, Accessories
Technical Data

Edition GB – T12

2

2

 

3
3
3

4-5

4
4
5
5
5
5

6

6-7

6
6
7

8

8

9

8-12

8
9

10
11
12

Summary of Contents for MKT 250

Page 1: ...dify Mode Fan Mode Timer Functional Principle of the Cooling Process Maintenance and Care Cleaning the Filter Draining the Condensate Trouble Shooting Taking the Device Out of Service Warranty Environ...

Page 2: ...ains supply line Protect all electrical lines of the device from damage even from animals Select the extension lines of the mains supply line depending on the connected load of the device the line len...

Page 3: ...that the cooling effect can be maintained Observe the following notices Plug the air outlet hose in cluded in delivery onto the air outlet on the rear panel of the device Lock both catches on the air...

Page 4: ...splay 7 13 Green Set Temp LED 14 C F toggle button only on the remote control Operation The device is operated comfortably using the control panel on the device or the in frared remote control Keys wi...

Page 5: ...is pressed the display switches from the room temperature to the set tempera ture LED 13 lights up and shows the desired temperature for 15 seconds 7 Set the desired room temperature using the Timer T...

Page 6: ...ondensate Draining the condensate The condensate evaporates during operation and is then conducted outside with the exhaust air via the air outlet hose In case of extreme humidity the device collects...

Page 7: ...e and pull the mains plug 2 Place a flat tray under the condensate drain spout and remove the plug Fig 17 3 After the condensate has drained reinsert the plug firmly The device is not cooling properly...

Page 8: ...sign sub ject to alteration Control panel Evaporator fan Condenser Red Orange Yellow White Red Red Red Blue Blue Blue Blue Condenser Condenser Compressor Evaporator fan Reservoir motor Mains plug Whit...

Page 9: ...to the wall bushing To prevent cold bridges insulate the telescopic pipe with suitable insulating material Wall the telescopic pipe into the core hole in such a way that it is flush to both sides of t...

Page 10: ...O MKT 11 Fig 20 Device diagram of the MKT 250 Technical dimensions and design subject to alteration 28 31 29 30 17 18 25 19 20 15 24 32 22 8 10 9 5 16 7 6 21 4 13 14 11 26 27 12 23 1 2 3 33 Device Dia...

Page 11: ...824 15 Exhaust air pipe adapter 1106865 1106865 16 Condenser 1 5 F 1106866 1106866 17 Evaporator 1106894 1106894 18 Fan housing circulation air 1106822 1106822 19 Fan wheel circulation air 1106823 110...

Page 12: ...ume approx m 80 Temperature setting range C 16 up to 32 Temperature operating limits C r F 16 bis 35 35 bis 85 Refrigerant R 410A Operating pressure max cooling circle kPa 1900 2800 Refrigerant quanti...