background image

Unit dimensions

KWK 100-4R to 400-4R

All information in mm

C

M

N O

L

Cooling / heating outlet

Cooling / heating inlet

E

H

I

F

J

K

G

B

D

A

KWK

100-

4R

KWK

150-

4R

KWK

250-

4R

KWK

400-

4R

A

660

810

960

1110

B

480

480

480

480

C

220

220

220

220

D

70

70

70

70

E

95

95

95

95

F

249

249

249

249

G

393

393

393

393

H

96

96

96

96

I

185

185

185

185

J

42

42

42

42

K

156

156

156

156

L

415

565

715

865

M

70

70

70

70

N

275

275

275

275

O

345

345

345

345

17

Spare parts list

No.

Designation 

KWK 100-4R

KWK 150-4R

KWK 250-4R

KWK 400-4R

1

Unit cover

1111750

1111751

1111752

1111753

2

Finned heat exchanger 4 rows of tubes

1111746

1111747

1111748

1111749

3

Outlet grill

1111764

1111764

1111764

1111764

4

Control panel, right

1111765

1111765

1111765

1111765

5

Control panel, left

1111766

1111766

1111766

1111766

6

Fan unit, complete.

1111767

1111768

1111769

1111770

7

Air filter

1111773

1111774

1111775

1111776

8

Condensate tray

1111779

1111780

1111781

1111782

9

Condensate tray, valve assembly, vertical

1111785

1111785

1111785

1111785

10

Transformer, speed step

1111786

1111778

1111788

1111789

11

Condenser fan

1111794

1111795

1111796

1111797

12

Condensate connection

1111790

1111790

1111790

1111790

Exploded view of the units
KWK 100-4R to 400-4R

9

12

7

2

6

11

10

4

8

3

5

1

When ordering spare parts, please state the EDP and unit number (see name plate)!

Summary of Contents for KWK 100-4R

Page 1: ...KWK 100 4R KWK 150 4R KWK 250 4R KWK 400 4R Wall and ceiling chilled hot water units for heat pump systems Operation Technology Spare parts Edition GB F01 REMKO KWK 4R...

Page 2: ......

Page 3: ...or misprints Safety notes 4 Environmental protection and recycling 4 Transportation and packaging 4 Guarantee 5 Unit description 5 System layout 6 Operation 6 7 Shutdown 7 Care and maintenance 7 8 Tro...

Page 4: ...it and its components must be set up connected and operated in accordance with the use and operating conditions stipulated in this manual and comply with all applicable local regulations Mobile units...

Page 5: ...is designed for use indoors in the lower wall area vertical installation and for ceiling installation horizontal installation Operation is either individually or in groups using a room temperature co...

Page 6: ...r warm water generator which extracts heat from the medium or heats the medium in a heat exchanger The cooled heated operating medium is then fed once again to the unit in the medium circuit Room temp...

Page 7: ...nance work may only be carried out if the unit is disconnected from electrical power CAUTION Care Ensure the unit is protected against dirt mould and other deposits Clean the unit using a damp cloth D...

Page 8: ...Switch the power supply and the unit back on Cleaning the condensate pump accessory The indoor unit may contain an integrated or separate condensate pump which pumps any accumulated condensate into ou...

Page 9: ...r wait for time period to pass Filter is dirty air inlet outlet opening is blocked by debris Have the filters been cleaned Clean filters Windows and doors open Heating cooling output has increased Hav...

Page 10: ...minimises the pressure loss in the lines Make all electrical connections in accordance with applicable DIN and VDE standards Always ensure the electrical cables are properly connected to the terminals...

Page 11: ...the heat exchanger slide into the retainer keep the same air duct and after installing the heat exchanger remove the film and screw the unit back together in reverse order 5 Removing the heat exchang...

Page 12: ...drainage line to the unit as described below Installation NOTE Installation should only be performed by authorised specialists Selecting the hydraulic connection 2 conductor cooling system Wall insta...

Page 13: ...ow rate adjusted using hydronic balancing valves Additional automatic bleed valves must be provided in the supply and return flows at the installation s highest point The medium piping must not exert...

Page 14: ...hich is not used must be permanently sealed a cap or similar CAUTION Condensate drainage connection Condensate drainage connection Condensate drainage connection Vertical mounting Horizontal mounting...

Page 15: ...ed KWK 100 4R to 400 4R Neutral conductor Phase conductor Earth conductor Power supply 230V 1 50Hz Level 2 Level 1 Level 3 Condensate pump If the condensate which forms is to be removed by a condensat...

Page 16: ...re and record all the required values in the commissioning report and check the safety functions 5 Check the unit control system using the functions described in the Chapter Operation Final tasks Reas...

Page 17: ...ned heat exchanger 4 rows of tubes 1111746 1111747 1111748 1111749 3 Outlet grill 1111764 1111764 1111764 1111764 4 Control panel right 1111765 1111765 1111765 1111765 5 Control panel left 1111766 111...

Page 18: ...6 5 26 5 27 5 36 5 25 5 26 5 34 5 Sound power level per stage dB A 34 37 43 34 41 45 35 36 45 34 35 43 Power supply V Hz 230 1 50 Enclosure class IP X0 Electr rated power consumption 1 kW 0 04 0 03 0...

Page 19: ...ssure power Level V l h dB A dB A QH kW LA C V l h QH kW LA C V l h QH kW LA C V l h QH kW LA C V l h KWK 100 4R min 128 25 5 34 0 48 31 83 0 69 35 9 119 9 0 91 41 1 159 3 1 13 46 196 8 5 147 28 5 37...

Page 20: ...in the field are more than just sales people above all they must be advisers to our customers in air conditioning and heating technology Customer service Our units operate precisely and reliably Howe...

Reviews: