Resetting the units
The malfunction (lock-out) of the
unit is displayed by the appearance
of a flashing triangle on the display
of the electronic temperature
regulation and the "Heating reset"
error code.
Proceed as follows to unlock:
Fault displays
The electronic temperature
regulation ATR-6 is capable of
displaying possible malfunctions
of the system and displaying
diagnosis notes:
Display:
The display goes out
completely.
Meaning:
The electronic
temperature regulation is
discharged because it was not
provided with electricity for more
than 5 hours.
Re-connect voltage supply, wait
until the display lights up again.
Time, day and desired room
temperatures must be re-
programmed.
The recharge of the buffer
capacitor lasts one hour.
All parameters required for the
operation of the unit are saved
in the control PCB without time
limitation.
Therefore, only day and time
as well as the desired switching
on/off programme must be re-
programmed.
The electronic temperature
regulation does not require any
special maintenance.
The use of cleansers and
detergents as well as sharp objects
should be avoided.
With interruption of voltage
supply for more than 5 hours,
the stored values in the
operating unit are lost.
ATTENTION
A reset may only be executed
20 seconds after the unit is
switched off.
ATTENTION
■
■
If the malfunction requires a
restore by the user, the symbol
appears on the display with the
key K1 (RESET)
■
If the cause of malfunction is
remedied, the normal operating
conditions can be restored
by pressing the key K1 and
operation can be resumed
■
By pressing the key K4, direct
access to the menu with
the possible error function
display of the burner and/
or the electronic temperature
regulation takes place
■
"N° (error number)" and the
corresponding number of the
fault appears on the display.
The faults (lock-outs) displayed
and stored by the system (control
PCB/electronic temperature
regulation) are the same as those
described in the section on fault
displays.
By pressing the key KM on the
electronic temperature regulation,
you arrive again at the Reset-
menu.
NOTE
When switching on the burner,
a small flame appears on
the display of the electronic
temperature regulation.
ATTENTION
Never interrupt the mains
connection prior to the
completion of the follow-up
cooling phase. There is no
warranty claim for damage to
the unit from overheating.