10
Discard the Unit
Transport Instructions
The unit features 2 casters, a handle and two recessed
grips on the sides for ease of transport.
The handle is integrated in the
rear panel of the unit and can be
pulled out upwards.
The recessed grips are located in
the side panels.
Handle
Recessed grip
Note:
◊
Always switch the unit off and unplug it before moving.
◊
Next, empty the condensation tank.
◊
Please pay attention to dripping condensation from
the vaporizer blades.
◊
Drain the condensation tank and wipe it dry with a
clean cloth.
Pay attention to dripping condensation from the va-
porizer blades.
◊
Clean the air intake and charcoal filters according to
their instructions.
Charcoal filters only ETF 150.
◊
Protect the unit from dust with a plastic cover.
◊
Store the unit in an upright position away from dust
and direct sun light.
Prior to longer idle periods
Continuous operation
A connector for a standard 1/2” water hose (not in-
cluded) is provided on the rear of the unit.
Ensure that the hose slopes downwards toward
the drain to permit condensation to drain without
obstructions.
G
To convert the unit from continuous to normal operation,
perform these steps in reverse order.
Remove the plug S from the
connector on the rear of the
unit.
S
Attach a sufficiently long hose to
the connector. The condensa-
tion can now be allowed to flow
into a drain, for example, during
unattended continuous opera-
tion.
To prevent spillage, ensure that the plug is cor-
rectly positioned!
G
Remove the condensation tank
and close the drain A below the
condensation trap with the plug
S. Replace the condensation
tank.
S
A
Remove the plug from the plug
socket.
Wrap the power cable on the re-
tainer on the rear panel of the unit.
Turn the knob of the hygrostat to
the “OFF” position.
Do not move the unit by pulling on the power
cable!
G
Working rang
Dehumidification performance depends exclusively
upon the design of the room, the room temperature and
humidity and the correct observance of the setup in-
structions.
See chapter “Installation”.
The dehumidification performance increases with the
room temperature and relative humidity.
For a reliable
operation the following working-range is
valid.
The proper functioning of the unit cannot be guar-
anteed at temperatures below 10 °C or a relative
humidity of less than 40%.
G
◊
Room temperature between 6 °C and 32 °C
◊
Relative humidity between 40% and 100%
After moving the unit, wait at least five minutes
before starting it to prevent damage to the com-
pressor.
G