Ventilation
Only the supply air fan operates in this setting.
Thermostatic regulation and heating operation are
not possible in this operating mode.
Switch the operating switch to the corresponding
position 1.
Fig. 4: Ventilation switch position
Heating with room thermostat (accessory)
The units operate fully automatically and according
to the room temperature.
1.
Pull out the strapping plug [2].
2.
Connect the room thermostat [4] plug [3] with
the thermostat receptacle [1] on the unit.
3
1
3.
Place the room thermostat [4] at a suitable
location in the room. The thermostat sensor
must not be located directly in the warm air
flow and must not be placed directly on a
cold floor.
4.
Set the desired temperature on the room
thermostat [4].
4
5.
Select the desired power position on the
operating switch.
6
Shutdown
1.
Switch the operating switch to the "0" (off)
position.
The supply air fan runs on to cool the units
and only switches off after the cooling down
phase is complete. The fan can switch on
and run several times before the final shut-
down.
2.
If shut down for an extended period, discon-
nect the units from the mains power supply.
NOTICE!
Never interrupt the mains connection prior to
the completion of the follow-up cooling phase.
There is no warranty claim for damage to the
units from overheating.
11