REMKO ATK
Installation instructions
Installation in enclosed, well
ventilated areas without
exhaust gas connection
■
Operation of the units is
permissible only if the minimum
air quantity for combustion is
supplied
■
Reliable extraction of
the combustion gases must
be guaranteed in all cases in
order to exclude impermissible
contamination of the room air
with hazardous substances
Fresh air is fed from below.
Exhaust gases are routed
upwards
Room heating
■
The units may only be operated
for room heating with a room
thermostat (accessories)
■
The fresh air supply required
for trouble-free combustion
must be ensured. It is practical
to have the fresh air supply
provided by windows and
doors or through appropriately
dimensioned openings in
the outside wall
The safety regulations of the accident
prevention and insurance associations,
the respective regional building
regulations and the combustion
appliances regulations apply to
operation of the unit.
■
Ensure that there is an adequate
fresh air supply appropriate to
the respective forced-air burner
capacity (see name plate)
Outdoor installation
■
Operation of the units must
not present a hazard or
unreasonable loading
■
The unit operator must
ensure that it is impossible
for unauthorised persons to
manipulate either the unit or
the power supply
■
To prevent damage due to
inclement weather, units
installed outdoors must be
adequately protected
NOTE
Overpressure and underpressure
in the installation area
should be avoided as this will
inevitably lead to combustion-
related faults.
NOTE
The electrical connection for
the units must be made at a
separate feed point with a residual
current device in accordance with
VDE 0100, Section 55.
NOTE
For optimum operation
the units should not be
operated above an ambient
temperature of 25 °C.
ATTENTION
The units must only be
installed in well ventilated
spaces and not in living areas
or similar recreational areas.
ATTENTION
In the event that the units are
operated through a power
generator, the generator must
be properly grounded.
NOTE
The burner setting must be
checked after every change
of location and adapted
to the new environmental
conditions and atmospheric
conditions if necessary.
Safety distances
■
In order to guarantee safe
operation and maintenance
of the units, a 1.5 m safety
distance must be maintained
around the unit
■
Flooring and ceilings must be
fire retardant
■
Intake and outlet diameters
must not be narrowed or
blocked with foreign objects
Electrical wiring
■
The units are
operated with
230 V/50 Hz
alternating current
■
The electrical connection is
made using a built-in mains
cable with earthed safety plug
■
Extensions to the cable
may only be carried out by
authorised electricians, subject
to the length of the cable,
connected load of the unit and
taking into consideration how
the unit is used at its location
Summary of Contents for ATK 50-S