REMKO ATK 50-S Operation,Technology,Spare Parts Download Page 13

13

Spare parts list

When ordering spare parts, please state the EDP no., unit number and type (see name plate)!

No. Designation

EDP no.

No. Designation

EDP no.

01

Fuel tank

1103965

81

Terminal strip 

1103781

11

Carrier housing

1103966

82

Mounting

1103782

15

OV mounting

1103967

83

Auxiliary relay

1107375

18

Steel tubular frame

1103968

84

O-ring

1103783

19

Locking ring

1101622

85

Ignition cable 

1107137

20

Hubcap

1101623

88

6 A fuse

1103785

22

Oil pre-heater

1103969

89

Mains cable with IP 67 plug

1109942

23

Housing lower section

1103970

90

Safety temperature limiter

1103711

24

Axle support bracket

1103971

92

Tank cap with valve

1102166

27

Axle

1103972

95

Oil intake pipe

1103990

28

Wheel

1101621

96

Bolted connection ¼" M12 x 1.75 1103991

29

Stand

1103973

97

Air-inlet grille

1103992

30

Stabiliser

1103974

98

Fan blade

1103993

31

Intake connection port

1103975

99

Fan motor compl.

1103994

32

Cover

1103976

100

Condenser

1103995

34

Inspection cover

1103977

101

Solenoid

1103766

35

Rubber buffer

1103978

102

Fuel pump compl.

1109946

39

Fan housing

1103980

103

Pump coupling

1102936

40

STB support bracket

1103981

104

Connection nipple 1/4"

1111674

41

Cable gland

1103982

105

Connection nipple 1/8"

1111672

42

Counter nut

1103983

111

Fuel filter (one-way)

1102146

50

Combustion chamber compl.

1103984

112

Hose connection port 350 Ø

1103997

52

Burner pipe

1103985

113

Insulation

1103998

53

Safety connector

1111680

114

STB fastening clip

1103999

54

Air slide

1103729

116

Hose clip

1103762

56

Mounting plate

1103731

117

Oil hose flex.

1104000

57

Ignition electrode

1103986

118

Oil hose flex.

1104001

58

Nozzle mounting

1103987

119

Connection nipple 1/4"

1111674

59

Nut M14

1107134

121

Oil hose flex.

1104002

60

Baffle plate

1103730

122

Outlet nozzle

1103989

61

Photocell mounting

1111676

123

Mounting bracket for exhaust gas duct 1104003

62

Oil nozzle (1.0/80° W)

1103988

124

Oil drain screw

1103778

63

Photocell

1108209

125

Sealing ring

1103777

64

Oil pressure line (flex) 

1111673

126

Hose clip

1107141

69

Aftercooler thermostat

1107182

127

Bolted connection

1102146-4

70

Electrical assembly compl.

1109953

Without figure:

76

PG plate

1102533

Thermostat plug

1101020

77

Ignition transformer

1107143

Cartridge filter for oil pump

1102088

79

Thermostat socket

1101018

Connection cable for MV

1102825

80

Strapping plug

1101019

Fastening strap for exhaust gas duct

1000960

Summary of Contents for ATK 50-S

Page 1: ...Edition GB I02 REMKO ATK 50 S Automatic oil heater with built in oil burner tank and exhaust gas connection Operation Technology Spare parts...

Page 2: ......

Page 3: ...or on the unit itself Subject to modifications no liability accepted for errors or misprints Safety notes 4 Environmental protection and recycling 4 Unit description 5 Installation instructions 6 7 E...

Page 4: ...ed by untrained personnel The following notes must be observed in full The power plug must be pulled out of the mains socket before maintenance and repair work The units may only be operated by person...

Page 5: ...reset key 2 1 Unscrew the protective cap 1 2 Carefully press in the reset key 2 with a suitable tool 3 Screw the protective cap 1 back on again 4 Reset the automatic burner Operating sequence The sup...

Page 6: ...ge due to inclement weather units installed outdoors must be adequately protected NOTE Overpressure and underpressure in the installation area should be avoided as this will inevitably lead to combust...

Page 7: ...g the 1st BImSchV Units that are not expected to be operated for longer than 3 months in the same location are not subject to any approvals or monitoring as per the 1st BImSchV The units can be transp...

Page 8: ...suitable and clean fuels may be used ATTENTION In the event of defects that endanger the operational safety of the units operation of the units must be discontinued immediately and the supervisor inf...

Page 9: ...e of the units The units including combustion chamber and burner must be cleared of soot deposits dust and dirt after every heating period or according to the operating conditions The oil filters must...

Page 10: ...alues 7 Following maintenance work refit all parts carefully in reverse order NOTE When positioning the baffle plate 7 always ensure that the aperture 5 is not obscured by a strut on the plate s s s C...

Page 11: ...e pump run for extended periods without any fuel Never leave the units for extended periods with a pump that has run dry Exhaust gas analysis To perform the exhaust gas analysis the exhaust gas measur...

Page 12: ...s Exploded view of the unit B 69 B 54 52 53 32 34 35 97 31 99 39 98 42 41 123 111 116 100 117 15 22 119 101 102 104 103 105 30 18 11 A 80 1 125 126 95 92 121 27 24 28 19 70 23 40 114 90 113 50 112 122...

Page 13: ...40 STB support bracket 1103981 104 Connection nipple 1 4 1111674 41 Cable gland 1103982 105 Connection nipple 1 8 1111672 42 Counter nut 1103983 111 Fuel filter one way 1102146 50 Combustion chamber...