background image

© 2021 Pinnacle Climate Technologies, Inc. 

Propane Forced Air Heater User’s Manual 

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

5

ALWAYS install the heater so that it is not directly exposed 

to water spray, rain, dripping water, or wind.

 

Use heater in accordance with all local codes. In 

the absence of local codes, refer to The National 

Fuel Code, ANSI A223.1/NFPA 54.

 

This heater is shipped from the factory for use 

with propane (LP) gas only. Do not convert to 

any other gas. Installation must conform to local 

codes, or in their absence, with the standard for 

the Storage and Handling of Liquefied Petroleum 

Gases ANSI/NFPA 58 and the Natural Gas and 

Propane Installation Code CSA B149.1.

 

Gas supply connections should be checked by 

using a 50/50 soap and water solution. Never use a 

flame to check for gas leaks.

 

Locate LP cylinder at least 6 ft. (183 cm) (10 ft./305 

cm in Canada) from the heater, and do not direct 

heater discharge towards the LP cylinder unless it 

is at least 20 feet (610 cm) from the heater.

 

Use only the regulator and hose assembly provided 

with this heater. Inspect the regulator/hose 

assembly prior to each use of the heater. If there 

is excessive abrasion or wear, or if the hose is cut, 

replace it with the proper assembly shown in the 

parts list, prior to using the heater.

 

The hose assembly shall be visually inspected 

prior to each use of the heater. If it is evident there 

is excessive abrasion or wear, or the hose is cut, it 

shall be replaced prior to the heater being put into 

operation. The replacement hose assembly shall 

be that specified by the manufacturer.

Manifold, Minimum, and Maximum Inlet Pressure

40-GFA

60V-GFA 125V-GFA

150V-GFA

Man.

11" (279 

mm) W.C.

11" (279 

mm) W.C.

8.3" (211 

mm) W.C.

8" (203 

mm) W.C.

Min.

5 PSI (34.5 kPa)

Max.

Bottle Pressure

For use with propane 

(LP) gas only.

WARNING

Electrical Grounding In-

structions: This appliance is 

equipped with a three-prong (grounding) plug for 

your protection against shock hazard and should be 

plugged directly into a properly grounded three-

prong receptacle.

RISK OF ELECTRIC SHOCK!

SAFETY INFORMATION (CONT.)

The hose assembly shall be 

pro tected from traffic, building 

material and contact with hot surfaces both during 

use and while in storage.

X

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

RISK OF FIRE! DO NOT POSITION HEATER IN A DOWNWARD ANGLE. ALWAYS 

LOCATE HEATER ON A STABLE AND LEVEL SURFACE (SEE FIGURE 1)!

 Figure 1

UNPACKING

1.  Remove all packing items applied to heater for shipment. 

Keep plastic cover caps attached to inlet connector and 

hose / regulator assembly for storage.

2.  Remove all items from carton

3.  Check all items for shipping damage. If the heater is 

damaged, promptly inform dealer where you purchased 

the heater. 

The Propane (LP) gas 

pressure regulator 

and hose assembly 

supplied with the heater must be used without 

alteration. 

CAUTION

WARNING

WARNING

WARNING

WARNING

Summary of Contents for REM-125V-GFA-B

Page 1: ...ARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PA PER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOM MENDED BY THESE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CON...

Page 2: ...in well ventilated areas If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life DO NOT OPERATE THIS HEATER UNT...

Page 3: ...y 100 000 Btu Hr 29 kW heater rating Refer to Ventilation on page 8 for further instructions WHAT TO DO IF THE SMELL OF GAS IS PRESENT DO NOT attempt to light the heater Extinguish any open flame Shut...

Page 4: ...he Construction Industry or the Natural Gas and Propane Installation Codes CSA B149 1 Periodically monitor levels of CO CO and NO existing at the construction site at the minimum at the start of the s...

Page 5: ...ch use of the heater If it is evident there is excessive abrasion or wear or the hose is cut it shall be replaced prior to the heater being put into operation The replacement hose assembly shall be th...

Page 6: ...2 6 9 2 50 2 81 3 13 Maximum Operating Hours 10 5 10 5 22 18 Required Cylinder Lb kg 20 9 20 9 100 45 100 45 Fuel Type Propane Propane Propane Propane Heating Area Ft 2 m2 1000 93 1500 139 3125 290 3...

Page 7: ...ate on vapor withdrawal from the operating cylinder The amount of Propane LP used with this heater varies Both factors are The amount of gas in the cylinder of LP The temperature of the LP tank and it...

Page 8: ...h soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connections If bubbles appear there is a leak If a leak is found tu...

Page 9: ...ontrol knob CLOCKWISE to O OFF position See Figure 4 2 Turn gas supply OFF by turning the LP cylinder valve CLOCKWISE to close Always turn gas off at the propane supply cylinder s when the heater is n...

Page 10: ...7 D3 0 47 F R1 C1 R2 1 4WS 100k FH51 250V 2A YW396 03AV YELLOW YW396 03AV WHITE RY1 B ALD112 IGNITOR 1 3 1 3 RY RY1 A ALD112 D5 1N4007 C2 25V 47 F SG SD 40 GFA THERMAL SWITCH BLUE POWER CORD EARTH SHE...

Page 11: ...heater 1 If the heater input or output is restricted the inside temperature can become too hot Keep the areas in front and behind heater clear of obstructions 2 Replace control valve 3 Clean inside of...

Page 12: ...zle Nut 22 518 0001 22 518 0001 22 518 0002 22 518 0002 8 Handle 70 001 0103 70 001 0103 70 001 0103 70 001 0103 9 Fan 22 514 0001 22 514 0001 22 514 0002 22 514 0002 10 Cushion Pad 22 509 0001 22 509...

Page 13: ...acle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warran...

Page 14: ...AT RIAUX SOLIDES INFLAMMABLES TELS LES MAT RIAUX DE CONSTRUCTION LE PAPIER OU LE CARTON UNE DISTANCE S CURITAIRE DE LA CHAUFFERETTE COMME RECOMMAND DANS LES PR SENTES INSTRUCTIONS NE JAMAIS UTILISER L...

Page 15: ...s une aire bien ventil e Si les informations contenues dans ce manuel ne sont pas suivies la lettre un incendie ou une explosion peuvent survenir et causer des dommages mat riels des blessures ou la m...

Page 16: ...t rieur doit exister pour chaque 29 kW du r gime nominal de la chaufferette Voir la section Ventilation la page 8 pour plus de d tails QUE FAIRE SI UNE ODEUR DE GAZ EST D TECT E NE PAS tenter d allume...

Page 17: ...gaz naturel et de gaz propane Surveiller p riodiquement les niveaux de CO CO2 et NO2 pr sents sur le chantier au minimum au d but du quart de travail et apr s 4 heures Assurer un change d air par une...

Page 18: ...est coup le remplacer par l ensemble qui convient illustr dans la liste des pi ces avant d utiliser la chaufferette Pressions d entr e collecteur minimum et maximum 40 GFA 60V GFA 125V GFA 150V GFA Co...

Page 19: ...bre maximal d heures de fonctionnement 10 5 10 5 22 18 Bouteille requise en kg 9 9 45 45 Type de carburant Propane Propane Propane Propane Surface chauff e m 93 139 290 353 Circulation d air m3 min 8...

Page 20: ...rtie du robinet de la bouteille de propane comme sp cifi dans les normes am ricaines pour les sorties et les entr es de robinets d vacuation pour bouteille de gaz Une soupape de s ret en communication...

Page 21: ...r qu il n y a pas de fuites pr parer une solution 50 50 de savon vaisselle et d eau Appliquer cette solution sur tous les raccords du gaz Si des bulles apparaissent il y a fuite Si une fuite est d cou...

Page 22: ...1 Tourner le bouton de commande dans le sens HORAIRE la position d arr t O voir Figure 4 2 FERMER l alimentation en gaz en tournant le robinet de la bouteille de propane dans le sens HORAIRE Couper l...

Page 23: ...1 4WS 100k FH51 250V 2A YW396 03AV JAUNE YW396 03AV BLANC RY1 B ALD112 ALLUMEUR 1 3 1 3 RY RY1 A ALD112 D5 1N4007 C2 25V 47 F SG SD 40 GFA 60V GFA 125V GFA 150V GFA CN1 CN2 CN3 CN4 THERMORUPTEUR 1 3...

Page 24: ...p lev e d clenchant le thermorupteur qui teint l appareil 2 Robinet de commande endommag 3 Accumulation de poussi re ou de d bris l int rieur de la chaufferette 1 Si le d bit de la chaufferette est re...

Page 25: ...rou de gicleur 22 518 0001 22 518 0001 22 518 0002 22 518 0002 8 Poign e 70 001 0103 70 001 0103 70 001 0103 70 001 0103 9 Ventilateur 22 514 0001 22 514 0001 22 514 0002 22 514 0002 10 Tampon amortis...

Page 26: ...et d terminera s il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un...