background image

© 2021 Pinnacle Climate Technologies, Inc. 

Propane Forced Air Heater User’s Manual 

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

13

LIMITED WARRANTY

Pinnacle Climate Technologies, Inc. warrants this heater to 

the original retail purchaser only, to be free from defects in 

material and workmanship for a period of one (1) year from 

the date of initial purchase. This product must be properly 

installed, maintained and operated in accordance with the 

instructions provided.

Pinnacle Climate Technologies, Inc. requires reasonable 

proof of your date of purchase from an authorized retailer 

or distributor.  Therefore, you should keep your sales slip, 

invoice or cancelled check from the original purchase.  

This Limited Warranty shall be limited to the repair or 

replacement of parts, which prove defective under normal 

use and service within the warranty period, and which 

Pinnacle Climate Technologies, Inc. shall determine at its 

reasonable discretion. 

This warranty does not apply to products purchased for 

rental use. 

This Limited Warranty does not cover any failures or 

operating difficulties due to normal wear and tear, accident, 

abuse, misuse, alteration, misapplication, improper 

installation or improper maintenance and service by you 

or any third party.  Failure to perform normal and routine 

maintenance on the heater, shipping damage, damage 

related to insects, birds or animals of any kind, and damage 

due to weather conditions are also not covered.  

 

In addition, the Limited Warranty does not cover damage 

to the finish, such as scratches, dents, discoloration, rust or 

other weather damage, after purchase. 

All transportation costs for the return of damaged product 

or parts will be the responsibility of the purchaser. Upon 

receipt of damaged item, Pinnacle Climate Technologies, 

Inc. will examine the item and determine if defective. 

Pinnacle Climate Technologies, Inc. will repair or replace 

and return the item, freight pre-paid.

 

If Pinnacle Climate Technologies, Inc. finds the item to 

be in normal operating condition, or not defective the item 

will be returned freight collect. This Limited Warranty is 

in lieu of all other express warranties. Pinnacle Climate 

Technologies, Inc. disclaims all warranties for products that 

are purchased from sellers other than authorized dealers or 

distributors. 

AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS 

WARRANTY EXPIRES, Pinnacle Climate Technologies, 

Inc. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, 

INCLUDING WITHOUT LIMITATION THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle 

Climate Technologies, Inc. SHALL HAVE NO LIABILITY 

WHATSOEVER TO PURCHASER OR ANY THIRD PARTY 

FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, 

OR CONSEQUENTIAL DAMAGES. Pinnacle Climate 

Technologies, Inc. assumes no responsibility for any defects 

caused by third parties. This Limited Warranty gives the 

purchaser specific legal rights; a purchaser may have other 

rights depending upon where he or she lives. Some states 

do not allow the exclusion or limitation of special, incidental 

or consequential damages, or limitations on how long a 

warranty lasts, so the above exclusion and limitations may 

not apply to you.  

Pinnacle Climate Technologies, Inc. does not authorize any 

person or company to assume for it any other obligation 

or liability in connection with the sale, installation, use, 

removal, return or replacement of its equipment, and no 

such representations are binding on Pinnacle Climate 

Technologies, Inc.

Always be sure to specify the model number and serial 

number when making any claim with Pinnacle Climate 

Technologies, Inc. For your convenience, use the space 

provided below to list this information.

Model #:________________________________

Serial #:________________________________

Date of Purchase: ________________________

Locating Your Serial Number:

Your serial number can be found on a white label on the right side cover of your heater. It will begin 

with the letter “G” followed by 9 digits. For Example: G123456789. Have your Serial Number ready 

before calling customer service at 800-641-6996.

XXX-XXXXXXXX

Serial Number

Label

Summary of Contents for REM-125V-GFA-B

Page 1: ...ARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PA PER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOM MENDED BY THESE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CON...

Page 2: ...in well ventilated areas If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life DO NOT OPERATE THIS HEATER UNT...

Page 3: ...y 100 000 Btu Hr 29 kW heater rating Refer to Ventilation on page 8 for further instructions WHAT TO DO IF THE SMELL OF GAS IS PRESENT DO NOT attempt to light the heater Extinguish any open flame Shut...

Page 4: ...he Construction Industry or the Natural Gas and Propane Installation Codes CSA B149 1 Periodically monitor levels of CO CO and NO existing at the construction site at the minimum at the start of the s...

Page 5: ...ch use of the heater If it is evident there is excessive abrasion or wear or the hose is cut it shall be replaced prior to the heater being put into operation The replacement hose assembly shall be th...

Page 6: ...2 6 9 2 50 2 81 3 13 Maximum Operating Hours 10 5 10 5 22 18 Required Cylinder Lb kg 20 9 20 9 100 45 100 45 Fuel Type Propane Propane Propane Propane Heating Area Ft 2 m2 1000 93 1500 139 3125 290 3...

Page 7: ...ate on vapor withdrawal from the operating cylinder The amount of Propane LP used with this heater varies Both factors are The amount of gas in the cylinder of LP The temperature of the LP tank and it...

Page 8: ...h soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connections If bubbles appear there is a leak If a leak is found tu...

Page 9: ...ontrol knob CLOCKWISE to O OFF position See Figure 4 2 Turn gas supply OFF by turning the LP cylinder valve CLOCKWISE to close Always turn gas off at the propane supply cylinder s when the heater is n...

Page 10: ...7 D3 0 47 F R1 C1 R2 1 4WS 100k FH51 250V 2A YW396 03AV YELLOW YW396 03AV WHITE RY1 B ALD112 IGNITOR 1 3 1 3 RY RY1 A ALD112 D5 1N4007 C2 25V 47 F SG SD 40 GFA THERMAL SWITCH BLUE POWER CORD EARTH SHE...

Page 11: ...heater 1 If the heater input or output is restricted the inside temperature can become too hot Keep the areas in front and behind heater clear of obstructions 2 Replace control valve 3 Clean inside of...

Page 12: ...zle Nut 22 518 0001 22 518 0001 22 518 0002 22 518 0002 8 Handle 70 001 0103 70 001 0103 70 001 0103 70 001 0103 9 Fan 22 514 0001 22 514 0001 22 514 0002 22 514 0002 10 Cushion Pad 22 509 0001 22 509...

Page 13: ...acle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warran...

Page 14: ...AT RIAUX SOLIDES INFLAMMABLES TELS LES MAT RIAUX DE CONSTRUCTION LE PAPIER OU LE CARTON UNE DISTANCE S CURITAIRE DE LA CHAUFFERETTE COMME RECOMMAND DANS LES PR SENTES INSTRUCTIONS NE JAMAIS UTILISER L...

Page 15: ...s une aire bien ventil e Si les informations contenues dans ce manuel ne sont pas suivies la lettre un incendie ou une explosion peuvent survenir et causer des dommages mat riels des blessures ou la m...

Page 16: ...t rieur doit exister pour chaque 29 kW du r gime nominal de la chaufferette Voir la section Ventilation la page 8 pour plus de d tails QUE FAIRE SI UNE ODEUR DE GAZ EST D TECT E NE PAS tenter d allume...

Page 17: ...gaz naturel et de gaz propane Surveiller p riodiquement les niveaux de CO CO2 et NO2 pr sents sur le chantier au minimum au d but du quart de travail et apr s 4 heures Assurer un change d air par une...

Page 18: ...est coup le remplacer par l ensemble qui convient illustr dans la liste des pi ces avant d utiliser la chaufferette Pressions d entr e collecteur minimum et maximum 40 GFA 60V GFA 125V GFA 150V GFA Co...

Page 19: ...bre maximal d heures de fonctionnement 10 5 10 5 22 18 Bouteille requise en kg 9 9 45 45 Type de carburant Propane Propane Propane Propane Surface chauff e m 93 139 290 353 Circulation d air m3 min 8...

Page 20: ...rtie du robinet de la bouteille de propane comme sp cifi dans les normes am ricaines pour les sorties et les entr es de robinets d vacuation pour bouteille de gaz Une soupape de s ret en communication...

Page 21: ...r qu il n y a pas de fuites pr parer une solution 50 50 de savon vaisselle et d eau Appliquer cette solution sur tous les raccords du gaz Si des bulles apparaissent il y a fuite Si une fuite est d cou...

Page 22: ...1 Tourner le bouton de commande dans le sens HORAIRE la position d arr t O voir Figure 4 2 FERMER l alimentation en gaz en tournant le robinet de la bouteille de propane dans le sens HORAIRE Couper l...

Page 23: ...1 4WS 100k FH51 250V 2A YW396 03AV JAUNE YW396 03AV BLANC RY1 B ALD112 ALLUMEUR 1 3 1 3 RY RY1 A ALD112 D5 1N4007 C2 25V 47 F SG SD 40 GFA 60V GFA 125V GFA 150V GFA CN1 CN2 CN3 CN4 THERMORUPTEUR 1 3...

Page 24: ...p lev e d clenchant le thermorupteur qui teint l appareil 2 Robinet de commande endommag 3 Accumulation de poussi re ou de d bris l int rieur de la chaufferette 1 Si le d bit de la chaufferette est re...

Page 25: ...rou de gicleur 22 518 0001 22 518 0001 22 518 0002 22 518 0002 8 Poign e 70 001 0103 70 001 0103 70 001 0103 70 001 0103 9 Ventilateur 22 514 0001 22 514 0001 22 514 0002 22 514 0002 10 Tampon amortis...

Page 26: ...et d terminera s il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un...

Reviews: