Propane Forced Air Heater User’s Manual 

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

11

Problem

Possible Cause(s)

Solution

Fan does not turn when 

electricity is connected. 

1.  No electric power to heater.

2.  Blades of fan in contact with 

heater housing.

3.  Fan blades bent.

4.  Fan motor defective.

1.  Check current at outlet. If voltage 

is correct, inspect extension and 

power cords for cuts, frays or 

breaks

2.  Check housing for damage. Be 

sure there are no dents in the 

housing obstructing the fan.

3.  Straighten all fan blades.

4.  Replace motor assembly.

Heater will not fire (ignite).

1.  No spark at module.

2.  Corroded electrode.

1.  Inspect module wire. Re-attach 

or tighten if loose. Inspect spark 

module and replace if necessary. 

Inspect all other electrical 

components.

2.  Replace spark plug  

(multi-bracket assembly).

Heater stops running  

by itself.

1.  Temperature inside heater is too 

high, causing thermal switch to 

shut down operation.

2.  Damaged control valve.

3.  Dust or debris accumulated  

in heater.

1.  If the heater input or output is 

restricted, the inside temperature 

can become too hot. Keep the 

areas in front and behind heater 

clear of obstructions. 

2.  Replace control valve. 

3.  Clean inside of heater.

TROUBLESHOOTING GUIDE

STORAGE / MAINTENANCE

Always disconnect the heater from the LP cylinder 

before putting the heater into storage. If for any reason 

the heater is to be stored indoors, the tank MUST be 

disconnected from the LP cylinder, and the cylinder 

stored outdoors in a well-ventilated area, out of the 

reach of children, and in accordance with the Standard 

for Storage and Handling of Petroleum Gases, ANSI/

NFPA 58 - latest edition and Natural Gas and Propane 

Installation Code, CSA B149.1. The plastic valve plug or 

valve cover supplied with the cylinder must be re-in-

stalled on the valve to protect the fitting from damage.

NOTE: Installation and repair of this heater should be 

done by a qualified service person.

ALWAYS be sure to follow proper maintenance proce-

dures. This should include cleaning the inside of the 

heater once a month and checking the spark gap at 

least once a heating season. Re-gap the terminals to 

0.160” (4mm) 

Never store an LP 

cylinder inside of a 

building or near any 

other gas or oil burning 

appliances.

DANGER

Summary of Contents for REM-125V-GFA-B

Page 1: ...ARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PA PER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOM MENDED BY THESE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CON...

Page 2: ...in well ventilated areas If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life DO NOT OPERATE THIS HEATER UNT...

Page 3: ...y 100 000 Btu Hr 29 kW heater rating Refer to Ventilation on page 8 for further instructions WHAT TO DO IF THE SMELL OF GAS IS PRESENT DO NOT attempt to light the heater Extinguish any open flame Shut...

Page 4: ...he Construction Industry or the Natural Gas and Propane Installation Codes CSA B149 1 Periodically monitor levels of CO CO and NO existing at the construction site at the minimum at the start of the s...

Page 5: ...ch use of the heater If it is evident there is excessive abrasion or wear or the hose is cut it shall be replaced prior to the heater being put into operation The replacement hose assembly shall be th...

Page 6: ...2 6 9 2 50 2 81 3 13 Maximum Operating Hours 10 5 10 5 22 18 Required Cylinder Lb kg 20 9 20 9 100 45 100 45 Fuel Type Propane Propane Propane Propane Heating Area Ft 2 m2 1000 93 1500 139 3125 290 3...

Page 7: ...ate on vapor withdrawal from the operating cylinder The amount of Propane LP used with this heater varies Both factors are The amount of gas in the cylinder of LP The temperature of the LP tank and it...

Page 8: ...h soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connections If bubbles appear there is a leak If a leak is found tu...

Page 9: ...ontrol knob CLOCKWISE to O OFF position See Figure 4 2 Turn gas supply OFF by turning the LP cylinder valve CLOCKWISE to close Always turn gas off at the propane supply cylinder s when the heater is n...

Page 10: ...7 D3 0 47 F R1 C1 R2 1 4WS 100k FH51 250V 2A YW396 03AV YELLOW YW396 03AV WHITE RY1 B ALD112 IGNITOR 1 3 1 3 RY RY1 A ALD112 D5 1N4007 C2 25V 47 F SG SD 40 GFA THERMAL SWITCH BLUE POWER CORD EARTH SHE...

Page 11: ...heater 1 If the heater input or output is restricted the inside temperature can become too hot Keep the areas in front and behind heater clear of obstructions 2 Replace control valve 3 Clean inside of...

Page 12: ...zle Nut 22 518 0001 22 518 0001 22 518 0002 22 518 0002 8 Handle 70 001 0103 70 001 0103 70 001 0103 70 001 0103 9 Fan 22 514 0001 22 514 0001 22 514 0002 22 514 0002 10 Cushion Pad 22 509 0001 22 509...

Page 13: ...acle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warran...

Page 14: ...AT RIAUX SOLIDES INFLAMMABLES TELS LES MAT RIAUX DE CONSTRUCTION LE PAPIER OU LE CARTON UNE DISTANCE S CURITAIRE DE LA CHAUFFERETTE COMME RECOMMAND DANS LES PR SENTES INSTRUCTIONS NE JAMAIS UTILISER L...

Page 15: ...s une aire bien ventil e Si les informations contenues dans ce manuel ne sont pas suivies la lettre un incendie ou une explosion peuvent survenir et causer des dommages mat riels des blessures ou la m...

Page 16: ...t rieur doit exister pour chaque 29 kW du r gime nominal de la chaufferette Voir la section Ventilation la page 8 pour plus de d tails QUE FAIRE SI UNE ODEUR DE GAZ EST D TECT E NE PAS tenter d allume...

Page 17: ...gaz naturel et de gaz propane Surveiller p riodiquement les niveaux de CO CO2 et NO2 pr sents sur le chantier au minimum au d but du quart de travail et apr s 4 heures Assurer un change d air par une...

Page 18: ...est coup le remplacer par l ensemble qui convient illustr dans la liste des pi ces avant d utiliser la chaufferette Pressions d entr e collecteur minimum et maximum 40 GFA 60V GFA 125V GFA 150V GFA Co...

Page 19: ...bre maximal d heures de fonctionnement 10 5 10 5 22 18 Bouteille requise en kg 9 9 45 45 Type de carburant Propane Propane Propane Propane Surface chauff e m 93 139 290 353 Circulation d air m3 min 8...

Page 20: ...rtie du robinet de la bouteille de propane comme sp cifi dans les normes am ricaines pour les sorties et les entr es de robinets d vacuation pour bouteille de gaz Une soupape de s ret en communication...

Page 21: ...r qu il n y a pas de fuites pr parer une solution 50 50 de savon vaisselle et d eau Appliquer cette solution sur tous les raccords du gaz Si des bulles apparaissent il y a fuite Si une fuite est d cou...

Page 22: ...1 Tourner le bouton de commande dans le sens HORAIRE la position d arr t O voir Figure 4 2 FERMER l alimentation en gaz en tournant le robinet de la bouteille de propane dans le sens HORAIRE Couper l...

Page 23: ...1 4WS 100k FH51 250V 2A YW396 03AV JAUNE YW396 03AV BLANC RY1 B ALD112 ALLUMEUR 1 3 1 3 RY RY1 A ALD112 D5 1N4007 C2 25V 47 F SG SD 40 GFA 60V GFA 125V GFA 150V GFA CN1 CN2 CN3 CN4 THERMORUPTEUR 1 3...

Page 24: ...p lev e d clenchant le thermorupteur qui teint l appareil 2 Robinet de commande endommag 3 Accumulation de poussi re ou de d bris l int rieur de la chaufferette 1 Si le d bit de la chaufferette est re...

Page 25: ...rou de gicleur 22 518 0001 22 518 0001 22 518 0002 22 518 0002 8 Poign e 70 001 0103 70 001 0103 70 001 0103 70 001 0103 9 Ventilateur 22 514 0001 22 514 0001 22 514 0002 22 514 0002 10 Tampon amortis...

Page 26: ...et d terminera s il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un...

Reviews: