NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2015, Pinnacle Products International, Inc.
Kerosene Forced Air Heater User’s Manual
Maintenance
11
PUMP PRESSURE:
While heater is operating, turn adjusting screw
clockwise to increase, counter-clockwise to
decrease pressure. Correct pump pressure is as
follows:
Model Number
Pump Pressure
HH-45-KFA
3.0 PSI
HH-75T-KFA
4.0PSI
HH-125T-KFA
5.0 PSI
HH-175T-KFA
7.5 PSI
HH-215T-KFA
9.0 PSI
Tolerance ± 10%
NOZZLES:
Nozzles should be cleaned or replaced at least
once per heating season. Contaminated fuel could
make this necessary immediately. To clean dirt
from nozzle, blow compressed air through nozzle
front. It may be necessary to soak the nozzle in
1-K kerosene to loosen any dirt particles.
Figure 18
Adjusting Screw
Pressure Valve
Figure 19
Nozzle
Nozzle Face
Burner Head
Wiring Diagrams
75T / 125T / 175T / 215T-KFA With Optional Power Outlet
45-KFA Without Optional Power Outlet
75T / 125T / 175T / 215T-KFA Without Optional Power Outlet