Problem

Possible Cause

Solution

Burner fails to ignite

1. 

Air in gas line

 

 

2. 

Gas pressure from cylinder 

too low.

3. 

LP cylinder valve turned off

4. 

Obstruction in air 

passageway.

5.  Dirt in pilot orifice.

6. 

Safety switch in cylinder 

valve engaged.

 

7. 

Tipover switch engaged. 

1. 

Keep depressing the gas control 

knob for at least 30 seconds to 

remove any in line.

2. 

Check LP cylinder pressure. 

Tank may be empty.

3. 

Open LP cylinder valve.

4. 

Inspect and clean heater 

housing.

5.  Blow out, or clean pilot orifice.

6. 

Close LP cylinder valve. Wait 

1 min. for switch to click off. 

Reopen LP cylinder valve slowly.

7. 

Move heater to a level surface.

No spark created when 

ignited

1. 

Incorrect igniter electrode 

position.

2. 

Electrode damaged or 

broken.

3. 

Loose or disconnected 

igniter wire.

4. 

Broken igniter wire.

1. 

Properly position electrode

 

2. 

Replace the electrode.

 

3. 

Tighten or reconnect loose wire.

 

4. 

Replace igniter wire.

Heater stops running by 

itself

1. 

Thermocouple damaged

2. 

Gas control valve damaged.

3. 

Gas leak

4. 

Thermocouple not in contact 

with pilot flame.

5.  Tip-over switch damaged, 

or loose connection at tip-

switch.

6. 

Out of fuel.

1. 

Replace thermocouple.

2. 

Replace gas control valve.

3. 

Check all connections for leaks 

using 50/50 solution of dish soap 

and water. Repair any leaks 

found.

4. 

Clean inside of heater housing.

5.  Inspect tip-over switch and 

connections. Replace if 

necessary.

6. 

Replace LP cylinder

Troubleshooting Guide

Locating Your Serial Number:

Your serial number can be found on the heater’s rating label. It will begin with the letters PGCV 

followed by 8 digits. For Example: PGCV12345678. Have your Serial Number ready before calling 

customer service at 800-641-6996.

10

Summary of Contents for HH-18-PCH-A

Page 1: ...SONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL L...

Page 2: ...sed areas DANGER Not for use in residential living areas or in non adequately ventilated enclosed spaces Never bring or store a propane cylinder indoors DANGER If the information in this manual is not...

Page 3: ...USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of outsi...

Page 4: ...ed with this heater Inspect the regulator hose assembly prior to each use of the heater If there is excessive abrasion or wear or if the hose is cut replace it with the proper assembly shown in the pa...

Page 5: ...rnational Inc Convection Heater User s Manual Features HH 18 PCH A Specifications Model HH 18 PCH A BTU 6 600 12 000 18 000 Fuel Consumption Lbs hr 0 31 0 56 0 83 Heat Settings 3 Maximum Operating Hou...

Page 6: ...propane LP cylinder that has a connection device that is compatible with the hose and regulator assembly supplied Remove the back cover by sliding the cover straight up and away from the heater body P...

Page 7: ...e at the LP Cylinder immediately The Propane LP cylinder must also be equipped with the following A collar to protect the gas valve A shut off valve terminating a LP cylinder valve outlet as specified...

Page 8: ...OFF position turn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas...

Page 9: ...the valve knob 7 If heater fails to light or does not stay lit repeat steps 2 through 6 8 When the center burner panel stays lit turn the valve knob to the desired setting Shut Down Instructions 1 Tur...

Page 10: ...dance with the Standard for Storage and Handling of Liquefied Gasses ANSI NFPA 58 latest edition The plastic valve plug or valve cover supplied with the LP cylinder must be reinstalled on the valve to...

Page 11: ...d when ignited 1 Incorrect igniter electrode position 2 Electrode damaged or broken 3 Loose or disconnected igniter wire 4 Broken igniter wire 1 Properly position electrode 2 Replace the electrode 3 T...

Page 12: ...Front Panel 50 001 0170 21 Burner Assembly 50 005 0105 6 Heat Plate 50 002 0205 22 Reflector 50 003 0210 7 Inlet Connector 50 019 0110 23 Wind Cover A 50 018 0110 8 Manual Valve Assembly 50 013 0160 2...

Page 13: ...ernational Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle P...

Page 14: ..._____ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ___________...

Page 15: ..._______ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _________...

Page 16: ...2015 Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Toll Free 800 641 6996 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com...

Reviews: