background image

© 2015 Pinnacle Products International, Inc.

668 Stony Hill Road #302 Yardley, PA 19067 USA 

• 

Toll Free (800)-641-6996

Fax: (215)-891-8461 

• Web: www.pinnacleint.com • Email: [email protected]

Summary of Contents for HH-18-PCH-A

Page 1: ...SONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL L...

Page 2: ...sed areas DANGER Not for use in residential living areas or in non adequately ventilated enclosed spaces Never bring or store a propane cylinder indoors DANGER If the information in this manual is not...

Page 3: ...USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of outsi...

Page 4: ...ed with this heater Inspect the regulator hose assembly prior to each use of the heater If there is excessive abrasion or wear or if the hose is cut replace it with the proper assembly shown in the pa...

Page 5: ...rnational Inc Convection Heater User s Manual Features HH 18 PCH A Specifications Model HH 18 PCH A BTU 6 600 12 000 18 000 Fuel Consumption Lbs hr 0 31 0 56 0 83 Heat Settings 3 Maximum Operating Hou...

Page 6: ...propane LP cylinder that has a connection device that is compatible with the hose and regulator assembly supplied Remove the back cover by sliding the cover straight up and away from the heater body P...

Page 7: ...e at the LP Cylinder immediately The Propane LP cylinder must also be equipped with the following A collar to protect the gas valve A shut off valve terminating a LP cylinder valve outlet as specified...

Page 8: ...OFF position turn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas...

Page 9: ...the valve knob 7 If heater fails to light or does not stay lit repeat steps 2 through 6 8 When the center burner panel stays lit turn the valve knob to the desired setting Shut Down Instructions 1 Tur...

Page 10: ...dance with the Standard for Storage and Handling of Liquefied Gasses ANSI NFPA 58 latest edition The plastic valve plug or valve cover supplied with the LP cylinder must be reinstalled on the valve to...

Page 11: ...d when ignited 1 Incorrect igniter electrode position 2 Electrode damaged or broken 3 Loose or disconnected igniter wire 4 Broken igniter wire 1 Properly position electrode 2 Replace the electrode 3 T...

Page 12: ...Front Panel 50 001 0170 21 Burner Assembly 50 005 0105 6 Heat Plate 50 002 0205 22 Reflector 50 003 0210 7 Inlet Connector 50 019 0110 23 Wind Cover A 50 018 0110 8 Manual Valve Assembly 50 013 0160 2...

Page 13: ...ernational Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle P...

Page 14: ..._____ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ___________...

Page 15: ..._______ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _________...

Page 16: ...2015 Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Toll Free 800 641 6996 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com...