en
10
Installation
Indications,
functions and options
Messages
Commissioning
Operation and function
Display channels
Channel
Description
Connection terminal
Page
INIT
x*
ODB initialisation active
-
FLL
x*
ODB filling time active
-
STAB
x*
ODB stabilisation in progress
-
COL
x
Temperature collector
S1
TST
x
Temperature store
S2
S3
x
Temperature sensor 3
S3
TSTT
x*
Temperature store top
S3
S4
x
Temperature sensor 4
S4
n %
x
Speed R1
R1
hP
x
Operating hours R1
R1
hP1
x*
Operating hours R1 (if OBST is activated)
R1
hP2
x*
Operating hours R2 (if OBST is activated)
R2
kWh
x*
Heat quantity in kWh
-
MWh
x*
Heat quantity in MWh
-
TIME
x
Time
-
Adjustment channels
Channel
Description
Factory setting
Page
Arr
x
System
1
DT O
x
Switch-on temperature difference R1
6.0 K [12.0 °Ra]
DT F
x
Switch-off temperature difference R1
4.0 K [8.0 °Ra]
DT S
x
Set temperature difference R1
10.0 K [20.0 °Ra]
RIS
x
Rise R1
2 K [4 °Ra]
PUM1
x
Pump control type R1
PSOL
nMN
x
Minimum speed R1
30 %
nMX
x
Maximum speed R1
100 %
S MX
x
Maximum store temperature
75 °C [167 °F]
OSEM
x
Store emergency shutdown option
OFF
EM
x
Collector emergency temperature
130 °C [270 °F]
Collector emergency temperature if ODB is activated:
95 °C [200 °F]
OCC
x
Collector cooling option
OFF
CMX
x*
Maximum collector temperature
110 °C [230 °F]
OSYC
x
System cooling option
OFF