INSTALLATION
LOCATION
Locate the icemaker dispenser indoors in a well ventilated area. Avoid exposure to direct sunlight and/or heat
caused by radiation. Ambient room temperature must be in the range of 60
°
to 90
°
F. Do not install unit in an
enclosed area where heat build-up could be a problem. Note: Air flow direction and spacing required to Figure 1.
Consult Figure 1A and 1B for utility connection locations.
Consult Figure 2 for dimensions for mounting unit to the counter with the hardware provided. Note that the unit
must be level for proper operation.
The unit must be sealed to the counter. The template drawing (Figure 2) indicates the openings which must be
cut in the counter. Locate the desired position for the unit then mark the outline dimensions and cut-out loca-
tions using the template drawing cut openings in counter.
Apply a continuous bead of NSF listed silastic sealant (DOW 732 or equal) approximately 1/4”inside of the unit
outline dimensions, and around all openings. Then position the eater of the counter within the outline dimen-
sions. All excess sealant must be wiped away immediately.
PLUMBING
Connect the icemaker to a cold, potable water source, suitable for drinking. This water source must comply with
the basic plumbing code of the Building Officials and Code Administrators International Inc. (BOCA) and the
Food Service Sanitation Manual of the Food and Drug Administration. Do not install unit on a water softener
line. It is recommended that a hand shut-off valve and strainer be used on the incoming supply line. (See Figure
2 for size and location.) For proper operation of the incoming water supply pressure must be in the range of
30-90 PSIG. Install a pressure regulating valve if above this range!
IMPORTANT: To insure proper icemaker operation and also to reduce the frequency of water-related
service problems, a water filter should be installed. REMCOR recommends the use of one of the
following basic systems.
For specific recommendations on these filter systems for your local water conditions, consult with a distributor in
your area or contact the filter manufacturer.
Connect separate drain lines to all drain connections. See Figure 2 for size and location. These lines must pitch
downward to and open drain and must contain no traps, or improper drainage will result. Separate, not joined
drain lines are required to prevent back flow.
NOTE: In areas where consistently warm water temperatures are encountered, the use of a pre-cooler
in the water line is recommended to maximize the ice production of this unit.
ELECTRICAL
This unit is supplied with a 2 wire-with ground 6 foot long conductor and suitable plug for a standard 115 volt 20
amp circuit receptacle. This cord exits the unit through the base and should be routed per the National Electric
Code.
WARNING: Only qualified personnel should service internal components or electrical
wiring.