WARNING
Operation/Safety
methods may vary in accordance with the
working guidelines established by each utility or contractor.
For your own safety, ensure that you fully comply with
all safe operation guidelines required by your employer.
Consult your training or safety personnel or supervisor as needed.
HYDRAULIC SYSTEM REQUIREMENTS
Operating Pressure: 1200-2000 PSI (70-140 bar)
Max. Relief Setting: 2100 psi (145 bar)
Flow Range:
5-9 gpm
REL-TP3
7-10 gpm (26-45 lpm)
REL-TP4
Max. Backpressure: 250 psi
(17 bar)
Cooling System:
Required
Min. Filtration:
25 Micron
Sound Pressure
<85 dBA @ 1m
Hydraulic Fluids:
All hydraulic fluids that meet these listed specifications
or listed HTMA specifications may be used for this tool.
S. U. S.
@
100
O
F
(38
O
C) ...........................................
140 TO 225
@
210
O
F
(99
O
C) .......................................
40 minimum
FLASH POINT
.....................
340
O
F min.
(170
O
C min.)
POUR
POINT
.......................... -
30
O
F min.
(-34
O
C min.)
Hydraulic Hoses:
2500 psi (175 bar) minimum working pressure (Ref. J517)
H
ose assembly should include
fl
ush face quick disconnect
couplers as recommended b
y the HTMA.
(Hydraulic Tool Manufacturers Association)
CAPACITY
Intake Port:
3 in. (75mm)
3 in. (100 mm)
Discharge Port:
3” NPFT (75mm)
4” NPT (100 mm)
Discharge Capacity: Up to 450 gpm
Up to 875 gpm (3,312 lpm)
(Illustration pg 6)
(Illustration pg 6)
WEIGHT & CLEARANCE
Weight:
30 lbs.
60 lbs. (9.5 kg)
Height:
13” (over handle)
19 in. (over handle)
Width:
14” L x 12” W
19” L x 15” W