background image

The Reliable Automatic Sprinkler Co., Inc.,

 

103 Fairview Park Drive, Elmsford, New York 10523

Bulletin 135 

Rev
.

 H

Bulletin 135 

Rev.

 H

Model F1 
Residential Sprinklers for
Design Density of .05 gpm/ft

2

Types:

F1 Res 30 Pendent
F1 Res 30 Recessed Pendent/F2
F1 Res 30 Recessed Pendent/FP
F1 Res 49 Pendent
F1 Res 49 Recessed Pendent/F1
F1 Res 49 Recessed Pendent/FP
F1 Res 58 Pendent
F1 Res 58 Recessed Pendent/F1
F1 Res 58 Recessed Pendent/FP
F1 Res 76 Pendent
F1 Res 76 Recessed Pendent/F1
F1 Res 76 Recessed Pendent/FP
F1 Res 30 CCP Pendent
F1 Res 49 CCP Pendent
F1 Res 58 CCP Pendent
F1 Res 76 CCP Pendent
F1 Res 44 HSW
F1 Res 44 Recessed HSW/F2
F1 Res 58 HSW
F1 Res 58 HSW Recessed HSW/F2
F1 Res 44 SWC

Listings & Approvals 

Listed by Underwriters Laboratories Inc. and
UL Certified for Canada  (cULus)
NYC MEA 258-93-E

Slope Ceiling Approvals: 

Refer to Bulletin 035

Sprinklers for .10 Density: 

Refer to Bulletin 176

UL Listing Category

Residential Automatic Sprinkler

UL Guide Number

VKKW

Patents

US Patent No. 6,516,893 applies to the 
Model F1 Res 49 & 58 Pendent Sprinklers

Product Description

Model F1 Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are 

fast response sprinklers combining excellent durability, 
high sensitivity glass-bulb and low profile decorative  de-
sign.  The F1 Res Horizontal Sidewall sprinklers (Figs. 5, 6 
& 7) are equally attractive when above ceiling piping can-
not be used.  

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.

1.

2.

F1 Res 30, 49, 58 & 76 

Recessed Pendent / FP

F1 Res 30, 49, 58 & 76 

Recessed Pendent / F1

F1 Res 44 & 58 

Recessed HSW/F2

 F1 Res 30, 49, 58 & 76 

CCP Pendent

F1 Res 44 SWC

The 3mm glass-bulb pendent sprinklers permit the effi-

cient use of residential water supplies for sprinkler cover-
age in residential fire protection design.

The low flow F1 Res sprinklers are specially engineered 

for fast thermal response to meet the sensitive fire protec-
tion application needs of the latest residential market stan-
dards (UL 1626 Standard).  Upon fire conditions, rising 
heat causes a sprinkler’s heat-sensitive glass-bulb to shat-
ter, releasing the waterway for water flow onto the deflector, 
evenly distributing the discharged water to control a fire.

Technical Data:

Thermal Sensor:  Nominal 3mm glass-bulb 
Sprinkler Frame :  Brass Casting
Sprinklers’ Pressure Rating :  175 psi

Factory Hydrostatically Tested to 500 psi 

Thread Size:  ½” NPT (R½)
K-Factor:  3.0  (Actual)  -  F1  Res  30  Pendent  Sprinkler                            

4.9 (Actual) - F1 Res 49 Pendent Sprinkler 
5.8  (Actual) - F1 Res 58 Pendent & HSW Sprinkler
7.6 (Actual) - F1 Res 76 Pendent Sprinkler
4.4 (Actual) - F1 Res 44 HSW Sprinkler

Density:  Minimum 0.05 gpm/ft

2




Model F1 Res Sprinklers engineered for the lowest 

fl

 ows 

to meet the minimum design density of .05 gpm/ft

2

Summary of Contents for Pantman F1

Page 1: ...rofile decorative de sign The F1 Res Horizontal Sidewall sprinklers Figs 5 6 7 are equally attractive when above ceiling piping can not be used 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 1...

Page 2: ...h for installing Models F1 Res Recessed Pendent CCP SWC sprinklers use only the Model GFR2 sprinkler wrench for installing Model F1 Res Recessed HSW sprin klers use only the Model GFR2 Sprinkler Wrenc...

Page 3: ...5 5 x 5 5 17 64 3 12 0 0 83 20 x 20 6 1 x 6 1 20 75 7 16 7 1 14 Deflector to ceiling Maximum 4 100mm to 8 203mm Max Sprinkler Spacing ft m Flow gpm Lpm Pressure psi bar Sprinkler Identification Numbe...

Page 4: ...Inch mm Sprinkler Temp Rating Max Pressure psi bar Max Ambient Temp K Factor Sprinkler Length Inch mm F C F C 3 4 NPT R 17 32 13 5 155 175 68 79 175 12 100 150 38 66 7 6 2 25 57 Max Sprinkler Spacing...

Page 5: ...tion A Inch mm Max Recessed 7 16 11 Min Recessed 15 16 24 Note Sprinklers shown in Fig 3 and Fig 4 are not suitable for installation in ceil ings which have positive pressure in the space above Techni...

Page 6: ...ch mm Sprinkler Temp Rating F C Flow gpm Lpm Pressure psi bar Sprinkler Identification Number SIN 12 x 12 3 6 x 3 6 4 6 101 152 155 68 175 79 12 45 4 7 5 0 52 R3531 14 x 14 4 3 x 4 3 155 68 175 79 14...

Page 7: ...31 14 x 14 4 3 x 4 3 14 53 0 10 2 0 71 16 x 16 4 9 x 4 9 17 64 3 15 0 1 1 16 x 18 4 9 x 5 5 19 71 8 18 7 1 13 16 x 20 4 9 x 6 1 23 87 1 27 4 1 89 12 x 12 3 6 x 3 6 6 12 152 305 14 52 9 10 2 0 71 14 x...

Page 8: ...ndard finish Bronze Chrome plated White Polyester Special finish specify Recessed escutcheon assembly shall be a steel two piece escutcheon with adjustment Model F2 with adjustment Model F1 of push on...

Page 9: ...er Spe cial finish specify Recessed escutcheon assembly shall be a steel two piece escutcheon with adjust ment Model F2 with adjustment Model F1 of push on and thread off design with adjustment Mod el...

Page 10: ...hroughout the United States Canada and foreign countries Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dr...