Measures prior to commissioning
Operating_Manual_Fan_KXE_04_en.docx
46 / 128
N-EUPEX series, type A, B
80
95
110 125 140 160 180 200 225 250 280 315 350 400
n
[rpm]
s
[mm]
3
3
3
3
3
4
4
4
4
5.5 5.5 5.5 5.5 5.5
K
a
[mm]
±1
±1
±1
±1
±1
±2
±2
±2
±2
±2.5 ±2.5 ±2.5 ±2.5 ±2.5
3000
K
r
[mm]
0.15 0.15 0.15 0.15 0.2 0.2 0.2 0.2 0.25 -
-
-
-
-
K
w
[degrees]
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 -
-
-
-
-
1500
K
r
[mm]
0.2 0.2 0.2 0.25 0.25 0.3 0.3 0.3 0.35 0.35 0.4 0.4 0.5 0.5
K
w
[degrees]
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
1000
K
r
[mm]
0.2 0.25 0.25 0.25 0.3 0.35 0.35 0.4 0.4 0.4 0.5 0.5 0.6 0.6
K
w
[degrees]
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
RUPEX series, type RWN, RWS
162 178 198 228 252 285 320 360 400 450 500 560 630 710
n
[rpm]
s
[mm]
3.5 3.5 3.5 3.5 3.5 4.5 4.5 4.5 4.5 5.5 5.5 6.0 6.0 7
K
a
[mm]
±1.5 ±1.5 ±1.5 ±1.5 ±1.5 ±1.5 ±1.5 ±1.5 ±1.5 ±1.5 ±1.5 ±2.0 ±2.0 ±2.0
3000
K
r
[mm]
0.15 0.2 0.2 0.2 0.25 0.25 0.3 0.3 -
-
-
-
-
-
K
w
[degrees]
0.07 0.07 0.06 0.06 0.06 0.06 0.06 0.05 -
-
-
-
-
-
1500
K
r
[mm]
0.25 0.25 0.3 0.3 0.35 0.4 0.4 0.45 0.5 0.55 0.6 0.65 0.75 0.8
K
w
[degrees]
0.1 0.09 0.09 0.08 0.08 0.08 0.08 0.07 0.07 0.07 0.07 0.07 0.07 0.07
1000
K
r
[mm]
0.3 0.35 0.35 0.4 0.45 0.45 0.5 0.55 0.6 0.7 0.75 0.8 0.9 1.0
K
w
[degrees]
0.12 0.12 0.11 0.11 0.10 0.10 0.09 0.09 0.09 0.09 0.09 0.08 0.08 0.08
Table 8-1
Reference values for maximum permissible offsets, N-EUPEX series, type A, B
Table 8-2
Reference values for maximum permissible offsets, RUPEX series