INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS

1. 

Safety Rules

2. 

Package Contents

3. 

Installation Instructions

1. SAFETY RULES

For operation, maintenance, and troubleshooting information, visit 

modernforms.com/help.

2. PACKAGE CONTENTS

WARNING: 

All  parts  must  be  used  as  indicated  in  these 

instructions.  This  product  is  designed  for  use  only  with  the 

supplied  parts  and/or  accessories  designated  for  use  by  Modern 

Forms. Substitution of parts or accessories not designated for use 

with this product by Modern Forms could result in personal injury 

or  property  damage  and  will  void  the  warranty.  Contact  an 

authorized dealer or the manufacturer if any parts are damaged or 

missing.

WARNING: 

To reduce the risk of fire, electric shock, personal injury 

or damage to the fan or other items, mount the fan to a UL/cUL 

listed  outlet  box  marked  “FOR  FAN  SUPPORT”  with  the  screws 

provided with the outlet box.

CAUTION: To prevent electrical shock, ensure electricity has been 

turned off at the circuit breaker before beginning.

-

Read all instructions before installing.

-

All wiring must be in accordance with the National Electrical Code “ANSI/

NFPA 70” and local electrical codes. Electrical installation should be 

performed by a licensed electrician.

-

The outlet box and support structure must be securely mounted and 

capable of reliably supporting a minimum of 50 lbs (22.7 kg). Use only UL/

cUL listed outlet boxes marked “FOR FAN SUPPORT OF 70 LBS OR LESS.” Use 

only the screws and washers provided with the outlet box.

-

The fan must be mounted with a minimum of 7 ft (2.1 m) clearance from the 

trailing edge of the fan blades to the floor and a minimum of 1.5 ft (0.5 m) 

from the edge of the fan blades to the surrounding walls. 

-

To avoid personal injury or damage to the fan and other items, please be 

cautious when working around or cleaning the fan.

All set screws must be checked and re-tightened where necessary before 

installation.