2 OPERATION
14
ALPIN100 Manual © Copyright 2008 by Reimesch Kommunikationssysteme GmbH
2.8.
TUNE TABLE
The table below shows the approximate settings for the
TUNE
and
LOAD
knobs on each
band. These settings are not exact but they can give you a starting point for a faster tuning
of the amplifier.
Band
Tune
Load
1.8
66
85
3.56
29
48
7.05
49
81
10.1
15
30
14.25
44
38
18.15
87
81
21.25
39
56
24.92
57
54
28.5
22
39
50.2
15
14
These settings will vary from one amplifier to another.
2.9.
ALPIN100 US VERSION
In the US version the ALPIN100 amplifier is shipped with disabled operation on the
24-28 MHz range to comply with FCC Rules.
The PTT circuit will not work on this
band and even with keyed down PTT the TX LED will not light.
Operators with an
appropriate licence who want to operate on these bands should contact their ALPIN dealer
for a 24-28 MHz upgrade.