2 OPERATION
11
ALPIN100 Manual © Copyright 2008 by Reimesch Kommunikationssysteme GmbH
While the amplifier is heating up, the protection system will monitor all the important data.
Please have a look at page 15 for more information.
2.3.
STANDBY MODE
When the warming-up time is over, the ALPIN 100 will move to standby mode. Here you can
see the forward power for the first time, the reflected power, and the CAP meter. The fourth
row of the display is used to show individual and /or the most essential values of the
amplifier.
You may alter the displayed data with the
UP
and
DOWN
buttons next to the display.
The Following data will be shown:
•
Forward power
•
Temperature of the exhaust air
•
Drive RF power
•
Screen current
•
High voltage
•
Plate current
•
Antenna SWR
•
Reflected power
In standby mode the following values are measured: temperature of exhaust air, screen
current and high voltage. You can see all the values either in operate mode or in transmit
mode.
2.4.
OPERATE MODE
To enter the operate mode press the
OPR/STBY
button. After this, the green OPR LED will
light. Only in this mode you will be able to transmit.