background image

    The operator can choose the most suitable radius 

for use, by inserting the pin in the adjustment 
plate

    The decal specifies the radius values with 

the upper value stating the outer shackle 
position and the lower value stating the 
inner shackle position

    The operating dimensions can be found 

on page 19

PORTA

DAVIT

  QUANTUM

Variants &  

Options

.

Assembly Instructions

Ensure the radius adjustment pin is fully engaged before use.

Adjusting the Radius

19

7

7a

Summary of Contents for PORTADAVIT QUANTUM PDQ 1

Page 1: ...REIDLIFTING COM PORTADAVIT QUANTUM Assembly Operation Guide ...

Page 2: ...27 Lightweight Portable Safe Please read the following instructions and guidance notes carefully before using or operating the system They contain important information about how to handle and use the system in a safe and efficient way avoiding danger reducing repair costs and downtime and increasing the reliability and lifespan of the system They apply for Operation including preparation troubles...

Page 3: ... safe location where there is no risk of falling into the hazard or lift area Intended Use This product is intended to be used for the lifting of goods the lifting of personnel rope access or providing a safety anchor for the prevention of falls It is expected that all users of this product have the necessary medical and physical capabilities are fully trained and competent in its safe assembly an...

Page 4: ...a fall arrest system which is only as strong as the lowest rated component Each lift must be properly planned and all weights clearly known along with the WLL and constraints of all fall arrest system devices Additional Notes for Correct Operation Ensure suitable and appropriately rated winches and connection plates are used for all applications Never walk away from the structure whilst connected ...

Page 5: ...is no wear or elongation on the bolt holes and ensuring that the jib section retracts smoothly Any necessary repairs should only be carried out by an approved specialist workshop using original spare parts It is recommended that once inspected or repaired the device is marked with the date of the next inspection Inspections are instigated by the user If detailed information is required on inspecti...

Page 6: ... more than 3 degrees from the horizontal Note Site specific information regarding the installation of REID davit sockets CANNOT be detailed within this operating manual as each site structure is different A qualified engineer MUST design and approve each installation based on the minimum mounting requirements site information and experience Minimum Mounting Requirements The supporting structure an...

Page 7: ...additional instructions should be followed Inspections must be instigated by the user prior to each use if used in a potentially explosive atmosphere Inspections and maintenance must be carried out at a safe distance away from an explosive atmosphere ATEX This product has been designed for use in explosive atmospheres in line with the following requirements and information Any use which differs or...

Page 8: ...f a socket extension is optional and the socket type may vary between a Top Mount Side Mount Bridge Mount Cast In or Resin Bonded depending on application Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructions Strop Column Restraint Point Kingpin Radius Adjustment Plates and Pin Head Lower Jib Carry Handle Connection Channel Telescopic Jib Pin Upper Jib Innovative...

Page 9: ...n Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructions Caution Potential finger trap Assembling the PORTA DAVIT QUANTUM Type W Winched Column Restraint Point Kingpin Sheave Bracket Assembly Head Lower Jib Carry Handle Harken LokHead Double Winch Bracket Assembly Radius Adjustment Plates and Pin Telescopic Jib Pin Upper Jib Rigid Backstay Sheave Adjustment Handle...

Page 10: ...the radius values with the upper value stating the outer shackle position and the lower value stating the inner shackle position The operating dimensions can be found on page 19 PORTADAVIT QUANTUM Variants Options Assembly Instructions Ensure the radius adjustment pin is fully engaged before use Adjusting the Radius 19 7 7a ...

Page 11: ...e front shackles in the head of the davit to support the rotation The rotation should be done in a controlled manner When the rotational handle is attached to the Davit the following points must be observed Attach the rotational handle to the column of the Davit at a suitable height Ideal position should be around hip height Secure in place with the pins provided See Figure 1 Rotate the handle upw...

Page 12: ... to inner shackle A B C D E A B C E D C E D B A C B A E D A E B C D Winched 296mm Radius Adjustment Points Dimensions mm Part Number WLL A B C D E PDQ1S 600KG 1 2007 1935 1799 1200 1100 2 2061 1989 1848 1100 1000 PDQ1W 3 2111 2039 1892 1000 900 PDQ2S 500KG 1 1837 1766 1647 1500 1400 2 1899 1827 1703 1400 1300 PDQ2W 3 1957 1885 1755 1300 1200 Radii achieved at 75 WLL 1680mm ...

Page 13: ... the IRATA Code of Practice and in doing so contributes to promote the development of safe systems Conformité Européenne CE UK Conformity Assessed UKCA REID Lifting s products have been designed tested and approved as appropriate by the Conformité Européenne and UK Conformity Assessed This certifies that REID Lifting s products meet the demands of the European and UK Directives and Regulations reg...

Page 14: ...engage before loading the system Insert the clevis pin and secure with the clip before loading the system Restraint point only Read the operational manuals before using the system Ensure the pin is fully engaged 1 Product Number 2 Serial Number 3 WLL 4 Year of Manufacture 5 Standards 6 ATEX 7 Max Moment The system is not suitable for fall arrest applications The system is suitable for fall arrest ...

Page 15: ...r The goods capacity WLL of the device The year of manufacture The standards to which the device is approved The ATEX rating of the product if applicable CE Marking Minimum braking load MBL Insert data from serial numbers found on product into table here Periodic Examination Repair History 29 PORTADAVIT QUANTUM Product Identification Inspection Record Notes ...

Page 16: ...31 PORTADAVIT QUANTUM Notes Notes ...

Page 17: ...om www reidlifting com Printed using environment friendly processes and materials All information herein is copyright protected by REID Lifting Ltd All company and product names are Trade Mark and Trade Name protected and all REID Lifting Ltd Product IPR is protected under Patents Patents Pending and or Design Rights Contact Us PDQ O M EN V5 08 2022 ...

Reviews: