5
PORTA
BASE
Inspection Prior to Initial Operation
Each product must be inspected prior to initial
operation by a competent person to ensure that the
structure is safe and that it has not been damaged
by incorrect assembly, transport or storage.
Inspection Before Starting Work
Before starting work, the product assembly and
all load-bearing components should be checked
for visual defects as per the inspection checklist on
page 16.
Maximum Capacity
Goods Lifting:
This product is designed to lift and
lower loads up to its rated capacity. Do not exceed
the capacity indicated on the system.
Personnel Lifting:
When lifting people, the overall
load limit is reduced by half to provide an increased
safety factor. The maximum capacity permitted by
the personnel winch/accessory used in conjunction
with the product also needs to be considered.
Please refer to the tables for information on
capacities and required amounts of counterweight.
The capabilities and counterweight stated in the
tables apply to standard range systems only. If you
are unsure about the system, consult the serial labels
information on page 31 or consult your supplier.
Temperature Range
This product can be operated in ambient dry
temperatures between –20°C and +55°C (-4°F
and 131°F). Consult your supplier in case of
extreme working conditions. If used in sub-
zero and wet conditions, fall arrest appliances
characteristics may change.
PORTABASE Maximum Capacity [kg]
Max Radius
800mm
1000mm
1200mm
Part Code
Description
Goods
Lifting
Personnel
Lifting
Goods
Lifting
Personnel
Lifting
Goods
Lifting
Personnel
Lifting
PBHB00001
H Base
600kg
300kg
x
x
x
x
PBCB00001
Counterbalance
600kg
300kg
500kg
250kg
400kg
200kg
For fall protection applictions see page 8.