Intended Use

This product is designed, tested and intended 
to be used for the lifting of goods, the lifting of 
personnel, rope access work or for providing 
a safety anchor for the prevention of falls as 
part of a personal fall protection system. (PFAS). 
The use of our products for these multiple 
applications is consistent with the products 
design, notwithstanding pre-user inspections and 
mandatory inspections by a competent or qualified 
person, determined by local regulations.

This product forms one part of a lifting system, the 
other part being a REID Lifting Davit. Before using 
the equipment, both Assembly & Operation Guides 
must be read.

Lifting of Goods:

 Each product will be marked with 

a Working Load Limit (WLL). The WLL is specifically 
intended as a maximum limit for the lifting of 
goods, materials and equipment and includes 
safety factors. 

Lifting of Personnel: 

For the lifting of personnel 

REID Lifting will reduce the WLL by half, thereby 
increasing the safety factor of the product. As 
for lifting goods, materials and equipment, the 
lowest rated element of the system always takes 
precedent. Associated equipment used for lifting 
personnel must be rated accordingly. It is the 
employers’ responsibility to ensure this is the case. 
For example, a winch must be personnel rated and 
where necessary, meet applicable standards and 
regulations for the country of use.

Correct Operation

Fall Protection Anchor:

 In most cases (subject 

to labelling and instructions for use for specific 
products confirming this) REID lifting products are 
tested and meet the requirements of fall protection 
standards and regulations, including EN795:2012 
and IRATA ICOP as referenced in our Instructions 
for Use. The WLL on the product is of no relevance 
to fall protection standards and requirements and 
the user should refer to the specific sections of the 
instructions for use, for detailed information. For 
example; EN795 requires that anchors that form part 
of a personal fall protection system are capable of 
withstanding a minimum 12kN static load for a single 
user and a further 1kN for each additional user. 
IRATA requires a 15kN static load. Additionally, fall 
protection systems are required to pass a series of 
dynamic performance tests. REID Lifting products 
will, where applicable be marked with the rating 
for fall protection. Safety factors will be higher than 
those for lifting and forces will be limited by the use 
of personal fall protection equipment, including 
load limiting devices such as shock absorbers or 
self-retracting lifelines that reduce impact forces, 
typically to a maximum of 6kN per user as required 
by law.

Note: some jurisdictions may not allow the same 
equipment to be used for lifting of materials and as 
a component of a PFAS. Some employers may also 
prefer to keep such equipment distinctly separate. 
If this is the case, we would recommend that the 
equipment is labelled accordingly Check your local 
regulations before putting equipment to use and 
designate accordingly.

It is expected that all users of this product have 
the necessary medical and physical capabilities, 
are fully trained and deemed competent in its 
safe assembly and use. We would remind users 
of the requirement to ensure that work is properly 
planned, risk assessments carried out and as 
required, method statements for carrying out work 
provided. 

Where required the owner/user of the equipment 
should ensure that a qualified person has been 
consulted in respect of the need for structural 
validation, for example (but not limited to); 
calculating imposed loads for the safety of ground, 
floor or roof structures during lifting operations.

Summary of Contents for PORTABASE PBCB00001

Page 1: ...REIDLIFTING COM PORTABASE Assembly Operation Guide...

Page 2: ...eration Warning IRATA Inspection Maintenance 16 Regular Inspections Maintenance Repair Storage Transportation ATEX 18 ATEX Classification Zone 2 Spark Formation Static Electricity Inspection Maintenan...

Page 3: ...and cleaning Maintenance inspection and repair Transportation It is the responsibility of the end user to adhere to the Health Safety and accident prevention standards and legislation valid in their r...

Page 4: ...uct is of no relevance to fall protection standards and requirements and the user should refer to the specific sections of the instructions for use for detailed information For example EN795 requires...

Page 5: ...ch accessory used in conjunction with the product also needs to be considered Please refer to the tables for information on capacities and required amounts of counterweight The capabilities and counte...

Page 6: ...g should only be carried out when the load chain forms a straight and vertical line between the load and lifting attachment point Only use this product when all leveling feet have been deployed and le...

Page 7: ...nces remove any weights from the basket during a lift Only applicable to the counterbalance system Allowable Rotation H Base The operating radius for the H Base is within the inside of the legs of the...

Page 8: ...versions are designated with a C at the end the product number on the serial label attached to each product Additional Notes for Correct Operation Warnings Always carry out pre use checks before using...

Page 9: ...west rated piece of equipment in the fall arrest system Ensure that you have read and understood the maximum force tables for each anchor point on the corresponding davit selected to be used with the...

Page 10: ...T Type S Davit Radius Anchor Point A Anchor Point B Anchor Point C Porta Base Fixed Socket 800 mm 22 2 kN 22 2 kN 22 2 kN 1000 mm 16 kN 16 kN 22 2 kN 1200 mm 16 kN 16 kN 22 2 kN Fixed Socket Only 1600...

Page 11: ...Point A Anchor Point B Anchor Point C Anchor Point D Porta Base Fixed Socket 800 mm 22 2 kN 22 2 kN 22 2 kN 22 2 kN 1000 mm 16 kN 16 kN 16 kN 22 2 kN 1200 mm 16 kN 16 kN 16 kN 22 2 kN Fixed Socket Onl...

Page 12: ...IT Type DW Davit Radius Anchor Point A Anchor Point B Anchor Point C Porta Base Fixed Socket 800 mm 22 2 kN 22 2 kN 22 2 kN 1000 mm 16 kN 16 kN 16 kN 1200 mm 16 kN 16 kN 16 kN Fixed Socket Only 1600 m...

Page 13: ...uced Radius PDQRW Davit Radius Anchor Point A Anchor Point B Anchor Point C 800 mm 16 kN 16 kN 16 kN This product was developed for the PORTABASE range including H Base and Counterbalance where the re...

Page 14: ...adius Anchor Point A Anchor Point B Anchor Point C P1 1000 mm 15 kN 15 kN 15 kN P2 1100 mm 15 kN 15 kN 15 kN P3 1200 mm 15 kN 15 kN 15 kN This product is designed for fixed sockets or with the PORTABA...

Page 15: ...sition Davit Radius Anchor Point A Anchor Point B Anchor Point C P1 1300 mm 12 kN 12 kN 12 kN P2 1400 mm 12 kN 12 kN 12 kN P3 1500 mm 12 kN 12 kN 12 kN This product is designed for fixed sockets or wi...

Page 16: ...Davit is fully engaged in the hub before applying a load Check the Davit in accordance with its corresponding Assembly Operation Guide Only applicable to the counterbalance system Inspections are inst...

Page 17: ...sent of the manufacturer Any necessary repairs identified during inspections should only be carried out by an approved specialist workshop using original spare parts Any repair must be carried out in...

Page 18: ...mists or by air and dusts mixtures are unlikely to occur or if they do occur are likely to do so only infrequently and for a short period only If the product is suitable for use in this environment it...

Page 19: ...hat could create electrostatic charging The structure is predominantly constructed from aluminium which will not rust However there are steel components used throughout Where there is sign of any rust...

Page 20: ...se system will be delivered in three components which are the Left Leg Assembly Right Leg Assembly and Central Hub Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructi...

Page 21: ...ctions and secure them into position with the R clips provided Insert the Davit into the Central Hub for use NB Please refer to the Assembly Operation Guide of the applicable Davit system when used in...

Page 22: ...ystem will be delivered in five components which are the Left Leg Assembly Right Leg Assembly Central Hub Tail and Basket Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly In...

Page 23: ...ded Repeat steps 1 and 2 for the second Leg Assembly securing the Leg Assembly to the Central Hub Insert the first Leg Assembly into the Central Hub Remove the pins from each side to unfold the basket...

Page 24: ...side plate between the end plate channels Ensure the side plate sits correctly over the pin Secure in place with the pins Repeat steps 7 10 for the second side plate Attach the basket to the tail and...

Page 25: ...of the Leveling Feet Insert the Davit into the Central Hub for use NB Please refer to the Assembly Operation Guide of the applicable Davit system when used in conjunction with the PORTA BASE 25 PORTAB...

Page 26: ...Variants Options...

Page 27: ...e height adjustment legs fully retracted as shown in figure 2 Position the system in place for the lift before setting the height Manually raise each leg in turn and set the height by rotating the han...

Page 28: ...Dimensions 332 450 1150 1600 1830 Max 1430 Min 115 mm Height Adjustment PORTABASE H Base...

Page 29: ...29 PORTABASE PORTABASE Counterbalance 2720 Max 2320 Min 2415 962 1950 240 140 320 638 600 92mm Height Adjustment...

Page 30: ...ombining quality systems management environmental issues and the health and safety practices within the company ISO 9001 2015 Quality management system which assesses an organization s ability to cons...

Page 31: ...ght portable and safe lifting solutions Innovation category 2006 and 2013 International Trade 2013 and 2018 Testing Testing and technical file review are integral parts of our design and manufacturing...

Page 32: ...Product labelling The following labels must be present on the product and must be legible 1 2 3 4 5 4 4 5 5 4 2 1 3 2 3 2 3 6 6 6 Product Labelling PORTABASE H Base...

Page 33: ...Product labelling The following labels must be present on the product and must be legible 1 2 3 4 5 4 4 4 5 5 5 5 6 2 1 3 6 6 6 3 3 2 2 3 3 33 PORTABASE PORTABASE Counterbalance...

Page 34: ...Notes...

Page 35: ...s unique serial number The goods capacity WLL of the device The year of manufacture The standards to which the device is approved The ATEX rating of the product if applicable CE Marking Periodic Exami...

Page 36: ...quiries reidlifting com www reidlifting com Printed using environment friendly processes and materials All information herein is copyright protected by REID Lifting Ltd All company and product names a...

Reviews: