11
PORTA
BASE
F = Maximum Rated Force
* Set up is indicative
30°
PFAS INFORMATION
T DAVIT [Type W]
Davit Radius
Anchor Point ‘A’
Anchor Point ‘B’
Anchor Point ‘C’
Anchor Point ‘D’
Porta Base & Fixed
Socket
800 mm
22.2 kN
22.2 kN
22.2 kN
22.2 kN
< 1000 mm
16 kN
16 kN
16 kN
22.2 kN
< 1200 mm
16 kN
16 kN
16 kN
22.2 kN
Fixed Socket Only
< 1600 mm
15 kN
15 kN
15 kN
22.2 kN
**Only Davits up to 800m radius can be used with the PORTABASE H Base System