1.  The  instrument 
does not work 

a) The current is not input 

Check  up on the plug receptacle  to see 
whether the hot line and neutral line are 
in  good  condition  or  not,  whether  the 
power  is  on  or  not,  and  whether  the 
voltage is normal or not. 

b) Broken safety wire(s) 

Change  the  safety  wire  10A  in  the 
power panel. 

c)  The  problem(s)  about  the 
switch of the current 

Change the identical type of switches. 

2. The conveyer belt 
does not work 

a)  The  conveyer  belt  is  too 
loose 

Fasten  the  belt  appropriately  and  stop 
fastening when it works. 

b) The triangle conveyer belt 
loosens   

Adjust it appropriately or change a new 
one. 

c)  The  inscribed  wire  of  the 
current panel loosens 

Check up and connect the wire. 

d)  The  electric  relay  is 
injured. 

Check  up  on  the  wiring  of  the  plug 
receptacle or change a new one. 

e) The button is injured. 

Check  up  on  the  button  of  “START”, 
and change a new one if required. 

3. The conveyer belt 
stops 

or 

reverse 

upon  pressing  the 
button of “START” 

a)  Iron  fragments  and  other 
contaminants  adhere  to  the 
conveyer 

belt 

and 

the 

detection devices 

a)

 

Clean  both  sides  of  the 
conveyer 

belts 

and 

the 

detection devices; 

b)

 

Change the belt if necessary. 

b)  There  exists  interference 
around the instrument 

a)

 

Eliminate the interference or be far 
away 

from 

the 

source 

of 

interference; 

b)

 

Change the location of operation of 
the  instrument  or  the  direction  of 
the instrument. 

c)  The  instrument  is  not 
installed well. 

Place  the  instrument  horizontally  and 
fix the boy-bolts. 

d)  The  level  of  sensitiveness 
is adjusted too high. 

Adjust the button to “5-7”. Note: If it is 
adjusted lower than “4”, it will decrease 
the  detection  capability  towards  the 
trivial needle tips.     

e)  The  drum  bearing  bears 
magnetism 

Change  a  new  bearing  that  is 
demagnetized 

and 

imported 

from 

abroad. 

4.  Trivial  iron  tips 
are undetected   

a)  They  are  smaller  than  the 
standard 

set 

by 

the 

instrument 

Adjust the level of sensitiveness higher 
appropriately. 

b) The  button  of the level  of 
sensitiveness is too low. 

Adjust the level of sensitiveness higher 
appropriately. 

c)  There  exists  strong  of 
electro-magnetism 
interference 

Eliminate  the  interference.  Shift  the 
phase. Connect the earth wire or change 
the location 

5. The conveyer belt 
can 

not 

work 

properly 

a)  The  conveyer  belt  is 
deviated. 

If the belt is deviated to the right, fasten 
the screws on the side of the instrument 
that has no electric motor or loosen the 
screws  on  the  left.  Minute  adjustment 
for  only  half  circle.  If  it  still  could  not 
return  to  the  center,  adjust  the  belt  for 
half  more  circle  in  accordance  to  the 
direction of the belt.     

The  conveyer  belt  is  edge  Adjust the conveyer belt. 

Summary of Contents for LX-630A Series

Page 1: ...630A Automatic Conveyance Magnetic Metal Detector User Manual For optimum performance and long term operation with no breakdown you should first of all read this Operating Manual with appropriate car...

Page 2: ...equipped with advanced switch power supply with good anti interference feature The voltage ranges within AC85 264V which only requires an electric motor with appropriate voltage With the advanced faci...

Page 3: ...nd the object to be detected can keep off the infrared beam reliably the instrument detects the circuit If the object to be detected is lower than 15mm or if it is translucent has a light leak and hen...

Page 4: ...trument b To press POWER the red button on the electric board and the START on the board of operation the conveyer belt will start operation The detection can then begin The conveyer belt will stop if...

Page 5: ...ion metal detector LX 630A is in accordance with the size and types of the objects to be detected which makes it possible to find the ferromagnetic varia and draw points among the products easily e It...

Page 6: ...re surrounding from 0 C to 40 C a place that will never be lower that the frozen point h There should not be any flowing dusts ferrous powder and abrasive grits in the place that locates the instrumen...

Page 7: ...iron nails and fragments among the object The repetition of the detection can ensure the safety e There might be wrong judge due to outside interference when the instrument is in operation for detect...

Page 8: ...t a Eliminate the interference or be far away from the source of interference b Change the location of operation of the instrument or the direction of the instrument c The instrument is not installed...

Page 9: ...be resolved Use the instrument in accordance to the Operating Manual Contact the Company Note The attached part for detection is the one that is under the standard testing Its sensitiveness differs in...

Reviews: