120 

φ

1.2 

LX-630A -150MM 

150 

φ

1.2-1.5 

LX-630A -200MM 

200 

φ

1.5-2.0 

1.

 

Voltage of the Power: AC100V-240V (single phase); 50-60HZ

±

10%. The machine will be 

supplied with AC220V, 50HZ as its standard if there is no special appointment while placing 

an order of it. 

2.

 

Power: 

<

140W; 

3.

 

Width of the Detection Pass: 600mm; 

4.

 

Speed of Conveyer Belt: 32m/min. (50HZ), 40m/min. (60HZ); 

5.

 

Adjustment of the Level of Induction: Consecutive adjustment from level 1 to 10; 

6.

 

Detection Approach: Magnetic induction; 

7.

 

Warning Pattern: Tingle of an electronic buzzer, pause or reverse of the conveyer belt, and the 

indication of the electro-luminescent lamp. 

 

Explanations of the Parts: 

1.

 

The control board of the power source: 

a)

 

The plug: while a plug receptacle with a good earth wire is plugged in, it is always 

required to adapt the voltage of the electric motor to the power source. 

b)

 

The power: the red indicator lamp lights when the switch is on; 

c)

 

The level: the level of induction increases when the adjustment goes up; 

d)

 

The AHEAD-BACK: a switch indicates the working status of the electric machine. When 

it is at AHEAD, the conveyer belt goes forward and stops after warning. When it is at 

BACK, it reverse after warning; 

e)

 

The  light:  infrared  opto-electronic  switch.  When  it  adapts  “On”  and  the  object  to  be 

detected can keep off the infrared beam reliably, the instrument detects the circuit. If the 

object to be detected is lower than 15mm, or if it is translucent, has a light leak and hence 

cannot  keep  off  the  infrared  beam  reliably,  the  switch  should  be  put  on  “OFF”.  The 

detecting circuit of the instrument maintains its working condition. Outward interference 

towards the instrument should be avoided. 

 

2.

 

The operational board: 

a)

 

The  counter:  six-digit  display.  The  principle  of  the  operation  is  that  if  the  object  to  be 

detected can keep off the infrared beam reliably for one time, the counter accumulative 

totals one. If the object to be detected is lower than 15mm, or if it is translucent and has 

light leap, the counter cannot work normally. It counts if the product is up to standard. It 

does  not  count  if  the  product  is  not  up  to  standard.  There  is  a  lithium  battery  in  the 

counter,  which  lasts  10  years  in  25

°

C.  The  “0”  button  indicates  erase.  The  “LOCK” 

may prevent people from pressing the button wrong. The button “ON”, which indicates 

the working condition, is on the right. The “OFF” disconnects the counter. 

b)

 

The DETECT 10N: the detection status 10 is a display window that is corresponding to 

the  ten  horizontal  sensors  for  the  pass  of  detection.  When  the  electro-luminescent 

lamplights,  it  indicates  that  a  foreign  matter  exists  in  a  location  it  is  passing.  If  the 

margin  of  the  display  lights  consistently,  it  indicates  that  there  exists  outward 

Summary of Contents for LX-630A Series

Page 1: ...630A Automatic Conveyance Magnetic Metal Detector User Manual For optimum performance and long term operation with no breakdown you should first of all read this Operating Manual with appropriate car...

Page 2: ...equipped with advanced switch power supply with good anti interference feature The voltage ranges within AC85 264V which only requires an electric motor with appropriate voltage With the advanced faci...

Page 3: ...nd the object to be detected can keep off the infrared beam reliably the instrument detects the circuit If the object to be detected is lower than 15mm or if it is translucent has a light leak and hen...

Page 4: ...trument b To press POWER the red button on the electric board and the START on the board of operation the conveyer belt will start operation The detection can then begin The conveyer belt will stop if...

Page 5: ...ion metal detector LX 630A is in accordance with the size and types of the objects to be detected which makes it possible to find the ferromagnetic varia and draw points among the products easily e It...

Page 6: ...re surrounding from 0 C to 40 C a place that will never be lower that the frozen point h There should not be any flowing dusts ferrous powder and abrasive grits in the place that locates the instrumen...

Page 7: ...iron nails and fragments among the object The repetition of the detection can ensure the safety e There might be wrong judge due to outside interference when the instrument is in operation for detect...

Page 8: ...t a Eliminate the interference or be far away from the source of interference b Change the location of operation of the instrument or the direction of the instrument c The instrument is not installed...

Page 9: ...be resolved Use the instrument in accordance to the Operating Manual Contact the Company Note The attached part for detection is the one that is under the standard testing Its sensitiveness differs in...

Reviews: