- 2 -
LX-630A -120MM
120
φ
1.2
LX-630A -150MM
150
φ
1.2-1.5
LX-630A -200MM
200
φ
1.5-2.0
1.
Voltage of the Power: AC100V-240V (single phase); 50-60HZ
±
10%. The machine will be
supplied with AC220V, 50HZ as its standard if there is no special appointment while placing
an order of it.
2.
Power:
<
140W;
3.
Width of the Detection Pass: 600mm;
4.
Speed of Conveyer Belt: 32m/min. (50HZ), 40m/min. (60HZ);
5.
Adjustment of the Level of Induction: Consecutive adjustment from level 1 to 10;
6.
Detection Approach: Magnetic induction;
7.
Warning Pattern: Tingle of an electronic buzzer, pause or reverse of the conveyer belt, and the
indication of the electro-luminescent lamp.
Explanations of the Parts:
1.
The control board of the power source:
a)
The plug: while a plug receptacle with a good earth wire is plugged in, it is always
required to adapt the voltage of the electric motor to the power source.
b)
The power: the red indicator lamp lights when the switch is on;
c)
The level: the level of induction increases when the adjustment goes up;
d)
The AHEAD-BACK: a switch indicates the working status of the electric machine. When
it is at AHEAD, the conveyer belt goes forward and stops after warning. When it is at
BACK, it reverse after warning;
e)
The light: infrared opto-electronic switch. When it adapts “On” and the object to be
detected can keep off the infrared beam reliably, the instrument detects the circuit. If the
object to be detected is lower than 15mm, or if it is translucent, has a light leak and hence
cannot keep off the infrared beam reliably, the switch should be put on “OFF”. The
detecting circuit of the instrument maintains its working condition. Outward interference
towards the instrument should be avoided.
2.
The operational board:
a)
The counter: six-digit display. The principle of the operation is that if the object to be
detected can keep off the infrared beam reliably for one time, the counter accumulative
totals one. If the object to be detected is lower than 15mm, or if it is translucent and has
light leap, the counter cannot work normally. It counts if the product is up to standard. It
does not count if the product is not up to standard. There is a lithium battery in the
counter, which lasts 10 years in 25
°
C. The “0” button indicates erase. The “LOCK”
may prevent people from pressing the button wrong. The button “ON”, which indicates
the working condition, is on the right. The “OFF” disconnects the counter.
b)
The DETECT 10N: the detection status 10 is a display window that is corresponding to
the ten horizontal sensors for the pass of detection. When the electro-luminescent
lamplights, it indicates that a foreign matter exists in a location it is passing. If the
margin of the display lights consistently, it indicates that there exists outward