7
│
REGULUS SRS6 EP Controller - www.regulus.eu
°C
0
10
20
30
40
50
60
70
80
90
100
Ω
1000 1039 1077 1116
1155 1194 1232 1270 1308 1347 1385
B 2 - Temperature sensors:
B 3 - Description
SRS6 EP Controller is designed for automatic control of solar thermal systems. The SRS6 EP model is inten-
ded to control solar thermal systems with up to 2 independent solar arrays and one or two solar consumers.
The solar consumers can be a hot water storage tank, a heat exchanger for a swimming pool, and a thermal
store for heating. All hydraulic variants are described in Chapter 2.
- both graphics and texts on a backlit display
- simple viewing of the current measurement values
- exact solar heat measurement
- analysis and monitoring of the system also by means of statistical graphics
- extensive setting menus with explanations
- menu lock can be activated to prevent unintentional setting changes
- usual preset parameters in factory setting
- further measurement and switching applications using a temperature difference and a thermostat
function
B 4 - Scope of supply
- SRS6 EP Controller
- 3 screws 3.5 × 35 mm for wall installation
- 6 strain relief clips with 12 screws
- replacement fuse 1xT2A/250V
- 5 temperature sensors