1. Introduction
RegulusRGMAT E W-iPWM Load Unit makes boiler installation quicker as it contains all components
needed for boiler circuit circulation and for boiler protection against low-temperature corrosion. It is
designed to be installed directly on return piping. The distance of pipe axis from a wall shall be at least
100 mm to enable insulation removal if needed.
This Load Unit is intended for hydronic fireplaces and solid-fuel boilers.
2. RGMAT E W-iPWM Load Unit Description
RGMAT E W-iPWM keeps the temperature in a hydraulic boiler circuit above the flue gas condensation
temperatures, which prevents so called low-temperature corrosion of the boiler combustion chamber.
This limits condensation and boiler tarring significantly, the efficiency of fuel combustion increases and
service life of the boiler is extended.
Main Features
Function
maintaining stable inlet temperature into a boiler (fireplace)
through a load valve
Application
Load Unit for solid-fuel boilers and fireplaces; it prevents low-
temperature corrosion and boiler (fire) fouling
Description
consists of Wilo PARA 25/8 iPWM1 pump, fittings w. integrated
ball valve, TSV3B valve (with automatic bypass balancing),
thermometer and insulation
Working fluid
water; water/glycol mixture (max. 1:1) or water-glycerine
mixture (max. 2:1)
Installation
on return piping, min. distance of the pipe axis from a wall is 100 mm
Codes
max. boiler output
18131 for 65°C opening temperature 31 kW
18133 for 55°C opening temperature 44 kW
Data for RGMAT E W-iPWM Pump Station
Fluid working temperature
5 - 95 °C
Max. working pressure
6 bar
Min. working pressure
0.5 bar
Ambient temperature
5 - 40 °C
Max. rel. humidity
80 % non condensing
Power supply
230 V, 50 Hz
Insulation material
EPP RG 60 g/l
Overall dimensions
305 x 170 x 135 mm
Total weight
3.3 kg
Connections
3x G 1" F
Accessories
Bypass with non-return valve
code 16 126