1. Introduction

RegulusRGMAT E W-iPWM Load Unit makes boiler installation quicker as it contains all components 

needed for boiler circuit circulation and for boiler protection against low-temperature corrosion. It is 

designed to be installed directly on return piping. The distance of pipe axis from a wall shall be at least 

100 mm to enable insulation removal if needed.

This Load Unit is intended for hydronic fireplaces and solid-fuel boilers.

2. RGMAT E W-iPWM Load Unit Description

RGMAT E W-iPWM keeps the temperature in a hydraulic boiler circuit above the flue gas condensation 

temperatures, which prevents so called low-temperature corrosion of the boiler combustion chamber. 

This limits condensation and boiler tarring significantly, the efficiency of fuel combustion increases and 

service life of the boiler is extended.

Main Features

Function

maintaining stable inlet temperature into a boiler (fireplace) 

through a load valve

Application

Load Unit for solid-fuel boilers and fireplaces; it prevents low-

temperature corrosion and boiler (fire) fouling 

Description

consists of Wilo PARA 25/8 iPWM1 pump, fittings w. integrated 

ball valve, TSV3B valve (with automatic bypass balancing), 

thermometer and insulation

Working fluid

water; water/glycol mixture (max. 1:1) or water-glycerine 

 

mixture (max. 2:1) 

Installation

on return piping, min. distance of the pipe axis from a wall is 100 mm

Codes

max. boiler output

18131 for 65°C opening temperature 31 kW 
18133 for 55°C opening temperature 44 kW 

Data for RGMAT E W-iPWM Pump Station

Fluid working temperature

5 - 95 °C

Max. working pressure

6 bar

Min. working pressure

0.5 bar

Ambient temperature

5 - 40 °C

Max. rel. humidity

80 % non condensing

Power supply

230 V, 50 Hz

Insulation material

EPP RG 60 g/l

Overall dimensions

305 x 170 x 135 mm

Total weight

3.3 kg

Connections

3x G 1" F

Accessories

Bypass with non-return valve  

code 16 126

Summary of Contents for RGMAT E W-iPWM

Page 1: ...www regulus eu RGMAT E W iPWM RGMAT E W iPWM EN Installation and Operation Manual RegulusRGMAT E W iPWM LOAD UNIT with PARA 25 8 for heating systems...

Page 2: ...n Features Function maintaining stable inlet temperature into a boiler fireplace through a load valve Application Load Unit for solid fuel boilers and fireplaces it prevents low temperature corrosion...

Page 3: ...der or even disable its operation Always respect valid rules and boiler manufacturer s data during installation Example of possible connection I Example of possible connection II The diagram shows a t...

Page 4: ...2 0 p m H 2 O Q m3 h A AB Kvs 6 2 m3 h B AB Kvs 4 4 m3 h B AB A The TSV3B load valve is fitted with an integrated thermostatic insert that will close the A inlet from a heating system if the return wa...

Page 5: ...calculation function The high efficiency circulation pumps of the PARA iPWM1 series are used exclusively for the circulation of liquids in hot water heating systems Operating the pump in other systems...

Page 6: ...RED IS LIT 1 rotor is blocked 2 electric motor winding defect FLASHING RED 1 power supply lower higher than 230 V 2 electric short circuit in pump 3 pump overheated FLASHING RED AND GREEN 1 unforced...

Page 7: ...7 5 6 Performace curves for Wilo Para 25 8 iPWM1 pump...

Page 8: ...iping or horizontally to the left of a boiler When being installed horizontally to the left of a boiler the Load Unit needs to be turned by 180 and the TSV3B valve turned as shown in the pics below FL...

Reviews: