REGULUS - R2GC storage water heaters - www.regulus.eu

3 - Technical Data and Dimensions of R2GC Tanks

Units

R2GC 200

R2GC 250

R2GC 300

R2GC 400

Volume 

[l]

200

250

300

400

Cold water inlet max. pressure

[MPa]

0.6

0.6

0.6

0.6

Max. working temperature

[°C]

100

100

100

100

Lower heating coil surface

[m

2

]

1

1.2

1.4

1.8

Lower heating coil volume

[l]

5.5

6.6

8.6

11.5

DHW heating 

Δ

t=35 °C (80/60 - 10/45) - lower heating coil

[kW]

34.6

41.5

48.5

62.3

Flow rate

[l/h]

850

1020

1190

1540

Upper heating coil surface

[m

2

]

0.7

1.0

1.1

1.3

Upper heating coil volume

[l]

4.5

5.5

6.4

7.4

DHW heating 

Δ

t=35 °C (80/60 - 10/45) - upper heating coil

[kW]

24.2

34.6

38.1

45

Flow rate

[l/h]

600

850

940

1110

Heating water needed

[m

3

/h]

2.7

2.85

3.0

3.0

h1

[mm]

210

130

210

240

h2

[mm]

290

210

290

320

h3

[mm]

400

355

440

570

h4

[mm]

570

520

580

770

h5

[mm]

500

620

760

870

h6

[mm]

570

680

780

900

h7

[mm]

640

740

845

980

h8

[mm]

710

910

1015

1150

h9

[mm]

820

1080

1090

1330

h10

[mm]

830

1010

1170

1310

h11

[mm]

900

1170

1260

1410

L

[mm]

1140

1300

1450

1660

D

[mm]

660

660

660

700

Weight

[kg]

98

122

133

162

G 1/2“ thermometer

Magnesium anode rod
For heating rod installation
Upper heating coil

Lower heating coil

Upper heating coil sensor sheath

Inspection hole

Lower heating coil sensor sheath

Openings for a heating rod and thermometer are located opposite the other ones.

G 5/4“

G 1“

G 1“

G 1“

ø 17×2

G 1“

ø 17×2

Hot water

Cold water

Circulation

Summary of Contents for R2GC 250

Page 1: ...R2GC 200 R2GC 250 R2GC 300 R2GC 400 STORAGE WATER HEATERS EN v 1 1 Users Manual Date of manufacture Serial number Checked by...

Page 2: ...3 Technical Data and Dimensions of R2GC Tanks 4 4 Operation 5 5 Examples of Assigning Connection Points 5 6 Installation and Commissioning 7 6 1 Connection to heat sources 7 6 2 Connection to a solar...

Page 3: ...d it guarantees a long serv ice life The magnesium anode rod shall be inspected regularly see point 7 Maintenance Replacement of Magnesium Anode Rod An electronic anode can be also used its lifetime c...

Page 4: ...5 upper heating coil kW 24 2 34 6 38 1 45 Flow rate l h 600 850 940 1110 Heating water needed m3 h 2 7 2 85 3 0 3 0 h1 mm 210 130 210 240 h2 mm 290 210 290 320 h3 mm 400 355 440 570 h4 mm 570 520 580...

Page 5: ...ystem R2GC HW CW recirculation E E gas boiler T bb bb bbb bbb B bbb bbb Conn point Example I with a gas boiler Example II with a boiler and accum tank G 5 4 upper flange magnesium anode magnesium anod...

Page 6: ...solar system and accumulation tank boiler PS R2GC HW CW recirculation E E T bb bb bbb bbb B bbb bbb Table of limit values for total dissolved solids in hot water Description pH Total dissolved solids...

Page 7: ...d to connect the tank to a cold water inlet and hot water outlet A 6bar safety valve shall be installed at the cold water inlet installa tion of a reducing valve is recommended If the pressure from wa...

Page 8: ...n anti corrosion sacrifice magnesium anode rod The anode rod shall be checked within 6 months after commissioning and subsequently always not later than 6 months after the last check If more than 1 3...

Reviews: