3 - Technical Data and Dimensions of R2GC Tanks
Units
R2GC 200
R2GC 250
R2GC 300
R2GC 400
Volume
[l]
200
250
300
400
Cold water inlet max. pressure
[MPa]
0.6
0.6
0.6
0.6
Max. working temperature
[°C]
100
100
100
100
Lower heating coil surface
[m
2
]
1
1.2
1.4
1.8
Lower heating coil volume
[l]
5.5
6.6
8.6
11.5
DHW heating
Δ
t=35 °C (80/60 - 10/45) - lower heating coil
[kW]
34.6
41.5
48.5
62.3
Flow rate
[l/h]
850
1020
1190
1540
Upper heating coil surface
[m
2
]
0.7
1.0
1.1
1.3
Upper heating coil volume
[l]
4.5
5.5
6.4
7.4
DHW heating
Δ
t=35 °C (80/60 - 10/45) - upper heating coil
[kW]
24.2
34.6
38.1
45
Flow rate
[l/h]
600
850
940
1110
Heating water needed
[m
3
/h]
2.7
2.85
3.0
3.0
h1
[mm]
210
130
210
240
h2
[mm]
290
210
290
320
h3
[mm]
400
355
440
570
h4
[mm]
570
520
580
770
h5
[mm]
500
620
760
870
h6
[mm]
570
680
780
900
h7
[mm]
640
740
845
980
h8
[mm]
710
910
1015
1150
h9
[mm]
820
1080
1090
1330
h10
[mm]
830
1010
1170
1310
h11
[mm]
900
1170
1260
1410
L
[mm]
1140
1300
1450
1660
D
[mm]
660
660
660
700
Weight
[kg]
98
122
133
162
G 1/2“ thermometer
Magnesium anode rod
For heating rod installation
Upper heating coil
Lower heating coil
Upper heating coil sensor sheath
Inspection hole
Lower heating coil sensor sheath
Openings for a heating rod and thermometer are located opposite the other ones.
G 5/4“
G 1“
G 1“
G 1“
ø 17×2
G 1“
ø 17×2
Hot water
Cold water
Circulation