background image

REGULUS - R2GC storage water heaters - www.regulus.eu

1 - Description

R2GC storage water heater (“tank” further on) is designed to accumulate heat for domestic hot water (DHW). 
The tank is heated from hot-water heat exchangers installed inside (2 heating coils). The lower heating coil 
can be used to connect e.g. a solar system while the upper heating coil can be fed from e.g. a gas-

fi

red boiler 

or an accumulation tank. The speed of heating up the tank to the desired temperature depends primarily on 
the 

fl

uid temperature entering the heat exchanger. Higher temperatures of the incoming 

fl

uid mean quicker 

heating up the tank, and vice versa. Should the output of the heat exchanger be insuf

fi

cient for some applica-

tions, an electric heating rod can be installed into the tank. 
The entire hydraulics of a heating system shall be designed properly in order to achieve 

fl

awless operation of 

the tank, i.e. the position of circulation pumps for heat sources and heating circuits, valves, check valves etc.

1.1 - Model line

These storage water heaters are supplied in four sizes: 200, 250, 300 and 400 l.

1.2 - Tank protection

The tank body is made of sheet steel, 

fi

nished outside with durable ecologic powder coating. Its inner enamel 

lining works as anticorrosion protection and together with a magnesium anode rod it guarantees a long serv-
ice life. The magnesium anode rod shall be inspected regularly - see point 7. Maintenance, Replacement of 
Magnesium Anode Rod. An electronic anode can be also used; its lifetime covers the lifetime of the tank if its 
operation indicator works right. 

1.3 - Thermal insulation

Tanks are insulated with ecologic 55 mm PUR foam (50 mm for R2GC 400) that reduces thermal loss to mini-
mum.

1.4 - Connection points

4× lateral, G 1“ female thread, for heating coils
2× lateral, G 1“ female thread, cold water in, hot water out
2× lateral, G 1/2“ female thread, for temperature probes
1× lateral, G 3/4“ female thread, for recirculation
1× upper, G 5/4“, for magnesium anode rod
1× lateral, G 6/4“ female thread, for electric heating rod
1× lateral, G 1/2“ female thread, for thermometer

1.5 - Packing

Tanks are delivered standing, each screwed to its pallet, shrink-wrapped. It is forbidden to transport and/or 
store the storage tanks in a horizontal position.

2 - General Info

The appliance shall be installed by a quali

fi

ed person according to valid rules.

This Users Manual is an integral and important part of the product and must be handed over to the User. Read 
carefully the instructions in this Manual as they contain important information concerning safety, installation, 
operation and maintenance. Keep this Manual for later reference.

Using the storage water heater for other purposes than above described is forbidden and the manufacturer 
accepts no responsibility for damage caused by improper or wrong use.

Summary of Contents for R2GC 250

Page 1: ...R2GC 200 R2GC 250 R2GC 300 R2GC 400 STORAGE WATER HEATERS EN v 1 1 Users Manual Date of manufacture Serial number Checked by...

Page 2: ...3 Technical Data and Dimensions of R2GC Tanks 4 4 Operation 5 5 Examples of Assigning Connection Points 5 6 Installation and Commissioning 7 6 1 Connection to heat sources 7 6 2 Connection to a solar...

Page 3: ...d it guarantees a long serv ice life The magnesium anode rod shall be inspected regularly see point 7 Maintenance Replacement of Magnesium Anode Rod An electronic anode can be also used its lifetime c...

Page 4: ...5 upper heating coil kW 24 2 34 6 38 1 45 Flow rate l h 600 850 940 1110 Heating water needed m3 h 2 7 2 85 3 0 3 0 h1 mm 210 130 210 240 h2 mm 290 210 290 320 h3 mm 400 355 440 570 h4 mm 570 520 580...

Page 5: ...ystem R2GC HW CW recirculation E E gas boiler T bb bb bbb bbb B bbb bbb Conn point Example I with a gas boiler Example II with a boiler and accum tank G 5 4 upper flange magnesium anode magnesium anod...

Page 6: ...solar system and accumulation tank boiler PS R2GC HW CW recirculation E E T bb bb bbb bbb B bbb bbb Table of limit values for total dissolved solids in hot water Description pH Total dissolved solids...

Page 7: ...d to connect the tank to a cold water inlet and hot water outlet A 6bar safety valve shall be installed at the cold water inlet installa tion of a reducing valve is recommended If the pressure from wa...

Page 8: ...n anti corrosion sacrifice magnesium anode rod The anode rod shall be checked within 6 months after commissioning and subsequently always not later than 6 months after the last check If more than 1 3...