Regulus NBC 170 HP Installation And Operation Manual Download Page 3

NBC 170 HP - www.regulus.eu

1 - Description 

NBC Hot Water Storage Tank with one stainless-steel heat exchanger, G 3/4“ connections (e.g. to connect 
a heat pump).
For the correct functioning of the tank it is necessary to optimally design a hot water heating system including 
a heat source, safety elements and shut-off valves in compliance with the respective standards and rules. 
The hydraulic variant shall be selected respecting the heating controller used. For a connection example, see 
Chapter 5 of this document. 

1.1 - Models

One model of 162 l total capacity. 

1.2 - Tank protection  

The entire tank is made of stainless steel which guarantees a ling service life. Further qualitative improvement 
is reached thanks to a magnesium anode rod installed inside the tank.

1.3 - Thermal insulation 

Tanks are supplied with 50 mm thick EPU insulation, white surface.

1.4 - Connection points on the tank 

2× top with G 3/4“ inner thread, for the heating coil
2× top with G 3/4“ inner thread, for cold water inlet and hot water outlet
1× top for temperature sensors, G 1/2”
1× top with G 3/4“ inner thread, for recirculation
1× top with G 3/4“ inner thread, for magnesium anode rod
1× lateral G 1/2“ with drain valve

1.5 - Packaging 

Tanks are delivered standing, each screwed to its pallet, packed in bubble wrap. 

2 - General Information 

The appliance shall be installed by a qualified person according to valid rules and Manufacturer‘s Instructions.

This Manual is an integral and important part of the product and must be handed over to the User. Read carefully 
the instructions in this Manual as they contain important information concerning safety, installation, operation 
and maintenance. Keep this Manual for later reference.

Using the tank for other purposes than stated above is prohibited and the manufacturer accepts no responsibility 
for damage caused by improper or wrong use.

Summary of Contents for NBC 170 HP

Page 1: ...www regulus eu NBC 170 HP NBC 170 HP EN Installation and Operation Manual HOT WATER STORAGE TANK NBC 170 HP...

Page 2: ...mal insulation 3 1 4 Connection points on the tank 3 1 5 Packaging 3 2 General Information 3 3 Technical Data and Dimensions of NBC 170 HP 4 4 Operation 6 5 Examples of Assigning Connection Points 6 6...

Page 3: ...U insulation white surface 1 4 Connection points on the tank 2 top with G 3 4 inner thread for the heating coil 2 top with G 3 4 inner thread for cold water inlet and hot water outlet 1 top for temper...

Page 4: ...s NBC 170 HP Hot Water Storage Tank code 17615 pos connections height mm W1 G 3 4 F 1060 mm W2 G 3 4 F 1060 mm W3 G 3 4 F 1060 mm X1 G 3 4 F 1060 mm X2 G 3 4 F 1060 mm C1 G 1 2 F 1060 mm A1 G 3 4 F 10...

Page 5: ...al Heat exchanger material Insulation material Insulation outer surface Tank diam Tank diam with insulation Total tank height Tipping height Empty weight 42 kg 1075 mm 1233 mm polyurethane PU Dimensio...

Page 6: ...perature should be set to 55 60 C This temperature guarantees the best operation and at the same time it prevents formation of Legionella bacteria 5 Examples of Assigning Connection Points Table of li...

Page 7: ...nk instead of the magnesium one 6 4 Commissioning Earth the tank before commissioning The earthing screw is located at the marked place Fill the entire system with liquids and air vent Check all conne...

Page 8: ...the tank connection points 9 Disposal Packaging shall be disposed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of as household waste It s...

Reviews: