![Regulus HSK 350 K P-B Installation And Operation Manual Download Page 5](http://html1.mh-extra.com/html/regulus/hsk-350-k-p-b/hsk-350-k-p-b_installation-and-operation-manual_1434433005.webp)
5
│
4 - Operation
This tank is designed for storing heating water in closed pressure circuits with forced circulation. The stored heating
water transfers its heat to domestic hot water via the integrated heat exchanger. Hot water is thus heated in a continuous
manner.
The tank is suitable for installations with heat pumps and a RegulusBOX indoor unit.
Dimensions
pos. description
connection height [mm]
Heat sources
B1
Incoming from heat source
G 1“ F
1
390
B2
Return to heat source
G 1“ F
1
630
B3
Incoming from heat source
G 1“ F
1170
Heating system
H1
Flow to heating system
G 1“ F
1
530
H2
Return from heating system
G 1“ F
1
210
DHW heating
W1
Cold water
G 1“ F
1
725
W2
Return from heating system
G 1“ F
1
775
Control and safety
C1
Temperature sensor
G 1/2“ F
1
500
C2
Temperature sensor
G 1/2“ F
1
940
T
2
Thermometer
G 1/2“ F
1380
P
2
Safety valve
G 1/2“ F
1
210
Others
O
2
Air release
G 1/2“ F
1655