Regulus HSK 350 K P-B Installation And Operation Manual Download Page 4

 

4

3 - Technical Data and Dimensions of HSK 350 K P-B Thermal Store 

Technical Data

Total tank volume

340 l

Fluid volume in tank

319 l

DHW heat exchanger volume

21 l

DHW heat exchanger surface area

6 m

2

Max. temperature in tank

95 °C

Max. temperature in DHW heat exchanger

95 °C

Max. pressure in tank

4 bar

Max. pressure in DHW heat exchanger

10 bar

Tank diameter

550 mm

Tank diameter with insulation

750 mm

Tank overall height

1655 mm

Tank perimeter insulation thickness

100 mm

Bottom insulation thickness

50 mm

Top insulation thickness

120 mm

Tipping height

1740 mm

Empty weight without insulation

82 kg

Materials

Tank material

S235JR

DHW heat exchanger material

AISI 316L

Tank insulation material

fleece and polystyrene

Outer surface of the insulation

rigid polystyrene

Main Features

Application

Combination thermal store with integrated stainless-steel heat 

exchanger and a tight separating metal sheet is intended for 

heat accumulation and DHW heating. Thanks to its modified 

design and the tight separating metal sheet, just one zone 

valve is sufficient for switching between heating the upper  

and lower tank sections. The tank is suitable for installations 

with heat pumps and RegulusBOX indoor unit. The tank 

insulation is not included in supply and shall be ordered 

separately, see the code below.

Working fluid

water; water/glycol mixture (max. 1:1) or water-glycerine

mixture (max. 2:1) (tank); water (heat exchanger)

Tank Code

18628

Insulation Code

18837

Energy Efficiency Data (as per EC Regulation No. 812/2013)

Energy Efficiency Cla

C

Standing loss

74 W

Storage volume

340 l

Volume of supplied DHW (heated from 10°C to 40°C)

Heated volume

entire

entire

above separating metal plate

Backup heating

10 kW

none

10 kW

Flow rate [l/min]

8

12

20

8

12

20

8

12

20

Temperature in tank

60 °C

60 °C

60 °C

Hot water volume [l]

287

261

218

229

211

174

273

248

210

Temperature in tank

50 °C

50 °C

50 °C

Hot water volume [l]

207

165

132

165

135

111

197

159

127

Summary of Contents for HSK 350 K P-B

Page 1: ...www regulus eu HSK 350 K P B HSK 350 K P B EN Installation and Operation Manual THERMAL STORE with stainless steel DHW heat exchanger HSK 350 K P B ...

Page 2: ... Technical Data and Dimensions of HSK 350 K P B Thermal Store 4 4 Operation 5 5 Connection of HSK 350 K P B to a Heating System 6 6 Installation and Commissioning 7 6 1 Connection to heat sources 7 6 2 Connection to water mains 7 6 3 Commissioning 7 7 Installing Insulation on the Tank 7 8 Maintenance 8 9 Disposal 8 10 Warranty 8 ...

Page 3: ...ion The insulation is made of fleece 100 mm thick with a hard polystyrene surface 1 4 Packaging Thermal stores are delivered standing each screwed to its pallet packed in bubble wrap It is forbidden to transport and or store the thermal stores in a horizontal position 2 General Information This Manual is an integral and important part of the product and must be handed over to the User Read careful...

Page 4: ...anger and a tight separating metal sheet is intended for heat accumulation and DHW heating Thanks to its modified design and the tight separating metal sheet just one zone valve is sufficient for switching between heating the upper and lower tank sections The tank is suitable for installations with heat pumps and RegulusBOX indoor unit The tank insulation is not included in supply and shall be ord...

Page 5: ...door unit Dimensions pos description connection height mm Heat sources B1 Incoming from heat source G 1 F 1390 B2 Return to heat source G 1 F 1630 B3 Incoming from heat source G 1 F 1170 Heating system H1 Flow to heating system G 1 F 1530 H2 Return from heating system G 1 F 1210 DHW heating W1 Cold water G 1 F 1725 W2 Return from heating system G 1 F 1775 Control and safety C1 Temperature sensor G...

Page 6: ...tation for DHW recirculation CSE TVMIX ZV 8 safety kit for HW storage tank 9 DHW expansion vessel 10 RegulusBOX indoor unit SV cold water TV hot water CV hot water recirculation ÚT central heating heating system KK ball valve ZV check valve AOV automatic air vent valve PTR pressure temperature relief valve REDV pressure reducing valve optional VK drain valve SVE expansion vessel service valve PV Ú...

Page 7: ...orrosion or incrustation esp on heat transfer surfaces Quality of DHW shall meet the conditions shown in the Table of limit values for total dissolved solids in hot water on this page Fill the heating circuits with the appropriate fluids and air bleed the entire system Check all connections for leaks and verify the system pressure Set the heating controller in compliance with the documentation and...

Page 8: ...he tank with a soft cloth and a mild detergent Never use abrasive cleaners or solvents Check all connections for leaks 9 Disposal Packaging shall be disposed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of as household waste It shall be dropped off at a Local Waste Recycling Center Insulation shall be recycled as plastic and the steel ...

Reviews: