![Regulus HSK 350 K P-B Installation And Operation Manual Download Page 3](http://html1.mh-extra.com/html/regulus/hsk-350-k-p-b/hsk-350-k-p-b_installation-and-operation-manual_1434433003.webp)
3
│
1 - Description
The HSK 350 K P-B Combination Thermal Store with an integrated stainless-steel heat exchanger and a tight separating
metal plate is intended for storing heat and heating of domestic hot water. Thanks to the modified construction and the
tight separating plate, it is sufficient to use only one zone valve for switching between heating the upper and lower part
of the tank. The tank is suitable for installations with heat pumps and a RegulusBOX indoor unit.
1.1 - Models
One model of 340 l total volume with stainless-steel DHW heat exchanger.
1.2 - Tank protection
The thermal store has no inner surface finish, the outer surface is painted in gray. The DHW heat exchanger is made of
stainless steel.
1.3 - Thermal insulation
Thermal insulation is available as a separate item. For easier handling, the insulation shall not be fitted on the tank until it
reaches its definite place of installation. The insulation is made of fleece, 100 mm thick, with a hard polystyrene surface.
1.4 - Packaging
Thermal stores are delivered standing, each screwed to its pallet, packed in bubble wrap
It is forbidden to transport and/or store the thermal stores in a horizontal position.
2 - General Information
This Manual is an integral and important part of the product and must be handed over to the User. Read carefully
the instructions in this Manual as they contain important information concerning safety, installation, operation and
maintenance. Keep this Manual for later reference.
This appliance is designed to accumulate thermal energy and distribute it subsequently. It must be connected to
a heating system and heat sources. This appliance is suitable for continuous heating of domestic hot water.
Using the thermal store for other purposes than above described is forbidden and the manufacturer accepts no
responsibility for damage caused by improper or wrong use or filling procedure.
The appliance shall be installed by a qualified person according to valid rules, otherwise the warranty becomes null and
void.