background image

2

Precautions for use

Security

Transshipment

- Make sure that the power supply voltage of 

the  device  does  not  exceed  240v  AC,  or 
50Hz.

-  If  liquids  or  any  object  had  entered  the 

housing,  disconnect  the  electrolyser  and 
have  it  checked  by  a  qualified  technician 
before handing over the service.

- Prohibition of drilling the box.
- The  electrical  control  cabinet  must  be  find 

near  the  electrolyser  and  be  easy  to 
access.

-  This  device  is  not  disconnected  from  the 

power source as long as it stays connected 
to  the  electrical  control  cabinet,  even  if  it 
has been turned off.

- After turning off the power at means of the 

on/off switch, do not open the device before 
total extinction of the lights.

- Do not install the electrolyser nearby from a 

source of heat.

- Do not store product cans chemical near the 

device.

Keep  the  original  carton  and  the  packaging 
material; they will be very useful if one must 
ship the device back one day.
To  ensure  maximum  protection,  repack  the 
device as packed at the factory.

Phredo is an electrical device that must not 
be exposed to rain or moisture.
To  correct  the  pH,  never  use  hydrochloric 
acid but pH-ready to employment.
The  technical  room  must  be  correctly 
ventilated.
The  power  supply  must  be  protected 
upstream  by  a  differential  circuit  breaker 
30mA.
To avoid any risk of electrocution, open the 
box  only  for  its  installation  or  service 
intervention  (to  change  an  electronic  card), 
after having cut the power supply.

Advisory

Regul electronic designs and
manufactures on site, in France, 

all  of  its  products  of  salt  electrolysis,  pH 
regulation and water level regulation.

-   Y o u   h a v e   j u s t   b o u g h t   a 

Régul’Electronique device, thank you 

for your trust.
-   U n l e s s   o t h e r w i s e   s p e c i f i e d 
particularly,  the  guarantee  of  our 
devices are 3 years from the date of 
your invoice.
- The cells and the pH probes have a 
guarantee of one year.

-  Excluded  from  the  guarantee  are  all  wear  parts 
(fuses, batteries, seals, valves, pump etc ...)
- This warranty is limited to the suppliers of our Society. 
It consists of the repair, by us and in our workshops, 
defects in manufacturing and matter, that the customer 
will have to prove.
-  The  equipment  must  be  returned  to  us  Free  of 
charge.
Costs  of  removal,  rests  and  transportation  are 
excluded of the guarantee.
- In all cases, our liability is limited to replacement of 
defective parts without no compensation or damages 
and  interest  be  claimed  for  material  or  bodily  injury 
caused.
- The warranty ceases when our equipment is modified 
outside our workshops.
-  The  warranty  does  not  apply  to  replacements  or 
repairs that would result from normal wear and tear of 
material,  deterioration  or  accident  from  negligence, 
lack  of  supervision  or  maintenance,  non-conforming 
installation or abnormal use of the devices.
-  In  cases  of  inappropriate  treatments  and 
adjustments,  our  responsibility  cannot  be  engaged, 
especially  in  case  of  corrosion,  paint  snags  and 
defects related to excessive constraints of use, or if the 
equipment  must,  by  these  conditions,  be  brought  to 
work at too fast rates supported.

Régul’ Electronique

Summary of Contents for Double Phredo

Page 1: ...1 30062018 Phredo Double Phredo and Phredo SP SPE pH or Redox regulation or Doser Manual and installation DESIGNED AND MANUFACTURED IN FRANCE SINCE 1989 edition Phredo Peace of mind ...

Page 2: ...t the power supply Advisory Regul electronic designs and manufactures on site in France all of its products of salt electrolysis pH regulation and water level regulation Yo u h a v e j u s t b o u g h t a Régul Electronique device thank you for your trust Unless otherwise specified particularly the guarantee of our devices are 3 years from the date of your invoice The cells and the pH probes have ...

Page 3: ...ixation Device connections 6 PH and redox probes 7 Settings before getting started 8 Getting started The pH function 9 The redox function 10 The dosage function 11 Calibration and Setpoint The pH function 12 The redox function and Doser 13 Phredo SPE Piloting an electrolyser 14 Control of the functions 15 ...

Page 4: ...f the device has one The TAC must be at least 10 F or 100ppm this must be checked monthly if necessary add a TAC booster The chlorine stabilizer which is associated with the salt Aquaswim brought by the use of slow chlorine pebbles and shock chlorine pellets or manually should not exceed 20 mg l If products need to be added manually pH corrector they must be dissolved in a bucket or watering can a...

Page 5: ...ge to make sure it contains the following suction ballast injector flexible aspiration crystal tube Installer s manual rigid injection opaque tube Accessories Probe fixation x2 Dowels and fixing screws Support collars The Phredo Template ...

Page 6: ...eady occupies this terminal 13 needless to add a wire go to the next paragraph 2 Connect a power cable from the unit to the filter cabinet 2 x 1 5mm The phase brown wire on terminal 14 of the contactor auxiliary contact Neutral blue wire on the neutral bar 3 Plug the cable into the device on the screw terminal block intended for power supply on the electronic board brown on Pand blue on N Phredo T...

Page 7: ...probe must always be positioned vertically Installation of injection system 1 Drill the cap of the liquid container inject diameter 6mm pass the crystal tube and connect the suction ballast which go into the bottom of the can Connect the other end to the part left of the Phredo pump 2 Screw the injector on the reduction 1 2 3 8 Connect the opaque tube to it and the other end on the right side of t...

Page 8: ...lick to validate Click To increas or decrease a value The control button allows to enter the menu to change the displayed options by pressing a button turning it to modify and save values Turn clic The display lights up completely at each start for one second LCD Display The display lights up completely at each start for one second One of these segments is displayed when one of the functions This ...

Page 9: ...lic Choose clic clic Long Countdown clic Software version The pH function is already selected No need to change the Fct Calibration Volume of the pool Injection of pH plus or pH minus Setpoint For one second all lights of the display are on For one second the software version is displayed Then a countdown of 60 seconds starts during which it is possible to modify the following options Get started ...

Page 10: ...tdown clic ORP flashes Software version Choose the ORP function Calibration Volume of the pool Setpoint ORP For one second all lights of the display are on For one second the software version is displayed Then a countdown of 60 seconds starts during which it is possible to modify the following options Get started at the end of the countdown Adjust ORP flashes Function Redox Settings required for t...

Page 11: ...tdown clic Long Countdown clic Sofware version Choose the Dos function Setpoint ORP Dos For one second all lights of the display are on For one second the software version is displayed Then a countdown of 60 seconds starts during which it is possible to modify the following options Get started at the end of the countdown Adjust Dos flashes Function Dosage ...

Page 12: ...of the pH probe to the device Remove the cap probe protection and place it in the container of solution comes with the unit At all time it is possible to correct the wanted values The calibration of the probe is done under tension It is not necessary to use a standard solution if the pH in the pool is known precisely Régul Electronique basis 7 4 basis 50 basis 6 8 to 7 8 pH minus or pH plus clic c...

Page 13: ...clic clic Long Redox measurement clic ORP flashes Calibration Volume of the pool Setpoint Back to ORP measurement Adjust ORP flashes clic Long basis 1 0L 1cl to 9 9l clic Long clic Setpoint Adjust Dos flashes clic Long Displays the injected quantity Return to the display of the injected quantity Function Redox Function Dosage ...

Page 14: ...redo SPE Piloting an electrolyser The Phredo is equipped with a relay allowing to control a pump of big flow or piloting a electrolyseur for an indoor swimming pool Phredo SPE can control the chlorine production of an electrolyser by measuring redox in order to maintain a properly disinfected water It also limits the production of chlorine especially under firm shutter avoiding any risk of over ch...

Page 15: ... the pump by engaging the tube in its housing Replace the pump glass Message and check up Reading error regulation HS Probe empty canister The display flashes Indicates that the probe is at the limit of operation or calibration So change the probe dEF flashes when the pH or redox in the pool does not reach the injection setpoint Check the can is empty the measurement is too far from the instructio...

Page 16: ...16 ...

Reviews: