Location of control systems
Front view
Enclosure screws
On / Off switch
Digital display screen
BNC probe
Suction inlet
Peristaltic pump
Injection output
Power supply 240VAC
Classe II - câble 2 x 1,5mm²
Régul’ Electronique
- The pH must be between 7.2 and 7.4. A weekly check should be made
with a tester for correction on the pH (and thus make sure that the
regulation of pH is working properly if the device has one).
- The TAC must be at least 10 ° F or 100ppm, this must be checked
monthly, if necessary add a TAC booster.
- The chlorine stabilizer, which is associated with the salt (Aquaswim),
brought by the use of slow chlorine pebbles and shock chlorine pellets or
manually, should not exceed 20 mg / l.
- If products need to be added manually (pH corrector), they must be
dissolved in a bucket or watering can and spread on the surface water,
never put directly into the skimmer, after stopping the device.
Checks to be carried out before starting up the device
The use of hydrochloric acid is prohibited!