Regency Freestanding Woodstove
8
Minimum Alcove Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84" (2134mm)
Maximum depth of alcove - 36" (914mm)
Floor Protection
A combustible
fl
oor must be protected by non-combustible
material (like tile, concrete board, or certi
fi
ed to UL-1618 or
as de
fi
ned by local codes) extending beneath the heater and
a minimum of 6" (152mm) from each side and minimum 16"
(406mm) from the front face of the stove and minimum 6"
(152mm) (or the rear clearance to combustibles whichever
is smaller) from the rear of the stove.
When installed with horizontal venting, non-combustible
fl
oor
protection must beneath the
fl
ue pipe and extend 2" (51mm)
beyond each side.
Minimum Overall Width (X) of Floor
Protector
for all installations:
Stove
F2402M
36" (914 mm)
INSTALLATION
NOTE: In Canada, fl oor protection must extend 18" (450mm) to the
front and 8" (200mm) to each side and back of the stove.
From From Flue Min. Min.Hearth
Unit
Unit
Center-line Width to Rear Wall
G H
I J K L
Medium F2402M
with Airmate
15" (381 mm) 5.5" (139 mm) 27" (685 mm) 12" (304 mm) 54" (1371 mm) 48" (1219 mm)
with Rear Defl ector
15" (381 mm) 6.5" (165 mm) 27" (685 mm) 13" (330 mm) 54" (1371 mm) 49" (1244 mm)
Minimum Overall Depth (y) of Floor Protector
Unit
Residential
"C" Vent
Residentiial
Close Clearance
Mobile Home
Close Clearance
Alcove
Y
Z
Y
Z
Y
Z
Y
Z
Medium F2402M
with Airmate
with Rear Defl ector
46" (1168 mm)
46" (1168 mm)
6" (152 mm)
6" (152 mm)
45"*(1143 mm)
45"* (1143 mm)
5" (127 mm)
5" (127 mm)
45"*(1143 mm)
45"* (1143 mm)
5" (127 mm)
5" (127 mm)
45"*(1143 mm)
45"* (1143 mm)
5" (127 mm)
5" (127 mm)
*The rear clearance to combustibles is less than 6", for corner installations the rear corners may be angled to take advantage of the closer clearances.