Regency Freestanding Woodstove
14
compound. Secure the
fl
ashing to your roof with nails or screws.
5)
Place the storm collar over the
fl
ashing, sealing the joints with a silicone caulking.
6)
Fasten the raincap with spark screens (if
required) to the top of your chimney.
7)
For optimum ef
fi
ciency when installing into
a masonry chimney, size accordingly, i.e.
the 6" (152mm)
fl
ue dia. is 28.28 sq.in.
8)
To complete your chimney installation, install
the double wall connector pipe from the
stove’s
fl
ue collar to the chimney support
device.
9)
If you are using a horizontal connector,
the chimney connector should be as high
as possible while still maintaining the 18"
(457mm) minimum distance from the hori-
zontal connector to the ceiling.
10)
NOTE: Residential Close Clearance and
Alcove installations require a listed dou-
ble wall connector from the stove collar
to the ceiling level.
In addition to standard installation instructions
the following requirements are mandatory for
installation in a mobile home.
1)
The stove must be permanently bolted to
the
fl
oor of the Mobile Home using the
fl
oor
screws provided.
2)
The stove must have a permanent outside
air source for combustion.
3)
The stove must be electrically grounded to
the steel chassis of the Mobile Home.
4)
A listed double-wall connector chimney
system, roof thimble, spark arrestor and roof
fl
ashing kit suitable for use in Mobile Homes
must be used.
5)
If the chimney exits the Mobile Home at a
location other than through the roof, and exits at
a point 7ft. (2130mm) or less above the ground
level on which the Mobile Home is positioned
a guard or method of enclosing the chimney
shall be
fi
tted at the point of exit for a height up
to 7ft. (2130mm).
6)
The chimney shall be attached directly to
the room heater and shall extend at least 3 ft.
(914mm) above the part of the roof through
which it passes. The top of the chimney should
project at least 2ft. (610mm) above the highest
elevation of any part of the Mobile Home within
10 ft. (3048mm) of the chimney.
7)
The chimney system shall comply with Local
Requirements.
8)
Any openings in a chimney guard where
required must not permit the entrance of 3/4"
(19mm) diameter rod.
9) CAUTION: THE STRUCTURAL INTEGRITY
OF THE MOBILE HOME ROOF, FLOOR,
WALLS AND CEILING MUST BE MAIN-
TAINED.
10)
Check any other local building code as other
local codes may apply.
11)
WARNING: DO NOT INSTALL IN A SLEEP-
ING ROOM OF A MOBILE HOME.
12)
Use silicone to create an effective vapour
barrier at the location where the chimney or
other component penetrates to the exterior of
the structure.
INSTALLATION
CAUTION: At no time use unlabelled
parts, or substitute parts made for another
chimney system.
Install as per chimney manufacturer's
installation instructions.
WARNING: Operate only with door fully
closed - open feed door to feed fi re only.