Regency
®
PG36D Gas Log Fireplace
11
INSTALLATION
FLUEING
Regency
®
Direct Vent System (Flex)
Horizontal Terminations Only
These fl ueing systems, in combination with the PG36D Room Sealed Gas Fireplace, have been tested and listed as a Direct Vent type fl ue system
by the Australian Gas Association. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in
section "Exterior Flue Termination Locations."
Regency
®
Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the PG36D with a maximum
run of 1200mm.
1)
175mm dia. fl exible liner (1200mm length)
2)
100mm dia. fl exible liner (1200mm length)
3)
spring
spacers
(4)
4)
thimble
(2)
5)
AstroCap
termination cap (1)
6)
screws
(12)
7)
tube of Mill Pac (1)
8)
plated
screws
(8)
9)
screws #8 x 1-1/2" Drill Point, Stainless
Steel
(4)
If longer runs are needed, the Regency
®
Direct Vent system (Flex) # 946-516 includes
all the parts needed to install the PG36D with
a maximum 3.0m run.
1)
175mm dia. fl exible liner (3.0m length)
2)
100mm dia. fl exible liner (3.0m length)
3)
spring
spacers
(7)
4)
thimble
(2)
5)
AstroCap
termination cap (1)
6)
screws
(12)
7)
tube of Mill Pac (1)
8)
plated
screws
(8)
9)
screws #8 x 1-1/2" Drill Point, Stainless
Steel
(4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency
®
may be used for Flex installations.
3) If you are installing the PG36D into a Regency
®
Mantel Kit, use the minimum horizontal vent height (centre-line of 1029mm). Remember
to include the mantel base in your calculations and to maintain the 32mm clearance (38mm with Flex) to the underside of the mantel
top.
6-7/8"
(173mm)
dia. Flue pipe
4" (102mm)
dia. flue pipe
spring spacer
Termination Cap
(Part# 946-578/P)
AstroCap
(patented)
Wall Thimble