background image

6-7/8"

(173mm) dia.

Flue pipe

4" (102mm)
dia. flue pipe

Termination Cap
Part #946-523/P

AstroCap

spring
spacer

Wall Thimble (2 pc)

FPI Direct  Vent System (Flex)

Horizontal Terminations Only

These venting systems, in combination with the P36 / P36D Direct Vent 
Gas Fireplace, have been tested and listed as a direct vent heater system 
by Warnock Hersey. The location of the termination cap must conform 
to the requirements in the Vent Terminal Locations diagram.

FPI Direct Vent (Flex) System Termination Kits include all the parts 
needed to install the P36 / P36D using a fl exible vent.

FPI Kit # 

Length 

Contains:

#946-515

4 Feet

1)

 

6-5/8” fl exible liner (Kit length)

2)

 

4” fl exible liner (Kit length)

3)

 spring 

spacers 

(3)

4)

 thimble 

(2)

5)

 

AstroCap

 termination cap (1)

6)

 screws 

(12)

7)

 

tube of Mill Pac (1)

8)

 plated 

screws 

(8)

9)

 

S.S. screws #8 x 1-1/2” drill point, (4)

#946-516

10 Feet

Notes: 
1) 

Liner sections should be continuous without any joints or seams.

2) 

Only Flex pipe purchased from Regency may be used for Flex 
installations.

3) 

Horizontal sections must be supported every 3 feet.

Alternate Horizontal 

Termination Caps

Alternate:
Horizontal
Riser Vent
Terminal
Part# 640-530/P

Snorkel Terminations

Snorkel Terminations:

For installations requiring a vertical rise on the exterior of the building, 
14-inch and 36-inch tall Snorkel Terminations and the Riser Vent are 
available. Follow the same installation procedures as used for standard 
Horizontal Termination. NEVER install the snorkel upside down.

Below Grade Snorkel Installation (Dura-Vent Only)

If the Snorkel Termination must be installed below grade, i.e. basement 
application, proper drainage must be provided to prevent water from 
entering the Snorkel Termination. Refer to Rigid Pipe Installation 
instructions for details. Do not attempt to enclose the Snorkel within the 
wall, or any other type of enclosure.

P36 - P36D Gas Fireplace

If required by the external termination location the listed 
alternate termination caps may be used.  (Refer to Page 11)

37

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Summary of Contents for P36-NG4

Page 1: ... 4 921mm 36 1 4 921mm H Framing Height 36 1 4 921mm 37 1 4 946mm I Framing Depth 12 3 4 324mm 17 1 8 435mm J Corner Wall Length 42 7 16 1078mm 48 1219mm K Corner Facing Wall Width 60 1524mm 68 1727mm L Framed Chase Ceiling 46 1168mm 46 1 2 1181mm M Vent Centerline Height 40 1 2 1029mm 40 1 2 1029mm N Gas Connection Height 2 51mm 2 51mm O Gas Connection Inset 3 1 2 89mm 3 1 2 89mm P Gas Connection ...

Page 2: ...projection 3 1 1 2 8 Single Sidewall when using the Barcelona Surrround Mantel Clearances A B C D with Flush Glass or Hampton Cast 30 1 2 778mm 14 356mm 10 254mm 7 178mm with Bay Option 30 1 2 778mm 13 330mm 10 254mm 7 178mm with Flush Glass and Barcelona Surround 30 1 2 778mm 17 432mm 12 305mm 8 203mm with Tripoli Screen Door Kensington or Balmoral Front 30 1 2 778mm 20 508mm N A 12 305mm P36 P36...

Page 3: ...pe purchased from Regency may be used for Flex installations 3 Horizontal sections must be supported every 3 feet Alternate Horizontal Termination Caps Alternate Horizontal Riser Vent Terminal Part 640 530 P Snorkel Terminations Snorkel Terminations For installations requiring a vertical rise on the exterior of the building 14 inch and 36 inch tall Snorkel Terminations and the Riser Vent are avail...

Page 4: ...ible materials Minimum of 1 pipe section between elbows Note Must use optional flue adapter when using Rigid Pipe Part 510 994 Maximum 40 ft 12 2m Minimum 10 6 3 2m Minimum 8 6 2 6m Max 10 3m centerline to centerline Minimum 12 305mm Maximum 27 ft 8 2m 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 Vertical Height Feet 32 34 36 38 6 8 2 0 4 10 12 12 16 18 14 Rigid Pipe Adapter Part 510 994 Pipe Leng...

Page 5: ...x 6 Min F 5 Min 8 Max 7 Min Vertical Venting with Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 0 Min 2 Max 2 Min B 1 Min 2 Max 3 Min C 2 Min 3 Max 4 Min D 3 Min 4 Max 6 Min E 4 Min 5 Max 7 Min F 5 Min 6 Max 8 Min G 6...

Page 6: ... 10 12 14 16 18 20 22 24 26 28 30 in the diagram shows allowable combinations when installing a P36 The darker shaded area in the diagram shows additional allowable combinations when installing a P36D Note Must use optional flue adapter Part 510 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and ...

Page 7: ... Venting with Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 0 Min 1 Max 1 Min 2 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 Max D 3 Min 2 Max 7 Min 5 Max E 4 Min 3 Max 9 Min 6 Max F 5 Min 4 Max 10 Min 7 Max ...

Page 8: ...ear Adapter Kit which contains the following Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Flue Adapter 945 45º Elbow Alternate Approved Caps 980 Vertical Termination Cap 991 High Wind Cap 923GK 3 Co linear Adapter with flashing The shaded area in the diagrams show the allowable vertical terminations Please refer to Page 11 Exterior Vent Terminations for additional guidelines on vent...

Reviews: