12
|
Liberty
®
L234-10 Direct Vent Gas Insert
|
12
installation
THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY
FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.
This appliance is designed to be attached to two 3" (76mm) co-linear
aluminium flex running the full length of the chimney. The flue length
must be a minimum length of 8' (2.44m) and a maximum of 35' (10.7m).
Periodically check that the vent is unrestricted.
Masonry chimneys may take various contours which the flexible liner will
accommodate. However,
keep the flexible liner as straight as possible,
avoid unnecessary bending.
VENTING
Alternative Approved Venting Components*
46DVA-VC Vertical Termination Cap
46DVA-VCH High Wind Cap
46DVA-GK 3" Co-linear Adaptor with flashing
In areas of consistently high winds, we recommend using the Simpson
Dura-Vent System 46DVA-GK adapter and 46DVA-VCH high-wind cap.
The Air Intake pipe must be attached to the inlet air collar of the termination
cap.
*NOTE: Simpson Duravent can only be used with 3" liners.
INSTALLATION WITH 3" & 3" LINERS
Part #
Description
948-305
3" Flex - 35 ft. (intake & exhaust)
946-529
Regency Co-linear DV Vertical Termination Cap & Flashing
The L234 is also approved for use with a 2" liner for air intake and a 3" liner
for exhaust. This would be suitable for a Class A wood burning chimney
with a minimum 6" round flue.
The chimney must be lined with one 2" diameter liner for intake and one 3"
diameter liner for exhaust. The minimum vent length is 8' and maximum is 35'.
INSTALLATION WITH 3" & 2" LINERS
Part #
Description
948-305
3" Flex - 35 ft. (exhaust)
948-316
2" Flex - 35 ft. (intake)
946-582 Regency Co-linear DV Ver tical Ter mination Cap,
Flashing & 2" Collar
Vent Run
Vent Restrictor
Position
Burner Aeration
Setting
8' to 20'
1"
3/16"
20' to 35'
3/4"
3/16"
NOTE: See instructions in the "Vent Restrictor Position"
section on positioning of the vent restrictor.
Vent Run
Vent Restrictor
Position
Burner Aeration
Setting
8' to 20'
1"
3/16"
20' to 35'
1"
1/8"
NOTE: See instructions in the "Vent Restrictor Position"
section on positioning of the vent restrictor.
Summary of Contents for L234-LP10
Page 37: ...Liberty L234 10 Direct Vent Gas Insert 37 37 warranty MAIN ASSEMBLY a ...
Page 38: ...38 Liberty L234 10 Direct Vent Gas Insert 38 parts list 537 924 Low Profile Faceplate ...
Page 39: ...Liberty L234 10 Direct Vent Gas Insert 39 39 notes ...
Page 44: ...44 Liberty L234 10 Direct Vent Gas Insert 44 warranty ...
Page 45: ...Liberty L234 10 Direct Vent Gas Insert 45 45 notes ...
Page 46: ...46 Liberty L234 10 Direct Vent Gas Insert 46 notes ...
Page 47: ......