installation
GAS CONNECTION
GAS CONNECTION WARNING:
Only persons licensed to work with gas piping may
make the necessary gas connections to this appliance.
1) When the appliance is to be installed into either an existing masonry
chimney system or factory built fireplace, thoroughly clean the
chimney before installation.
2) A 3/8" NPT gas supply pipe must be brought near the inlet hole.
The valve inlet is on the right side of the unit.
3) Locate the center point where the vent will pass through the chimney
above the appliance. Move the appliance into the exact location
where it is to be installed. Ensure that the Insert is level.
NOTE: This unit is equipped with a heat sensor thermodisc which
will prevent the blower from operating until the unit reaches the
correct temperature.
5) Install flashing.
6) Insert both liners into chimney, passing through the damper opening.
7) Install termination cap.
8) Connect the marked end of the liner to the exhaust collar of the
vent connector plate marked with an "E", seal connection with high
temperature silicone. Secure with gear clamp or screws.
NOTES:
1) Final gas connection should be made after unit is in place to avoid
damage to the liner when pushing the unit into position.
2) Mill-pac may be used instead of high temperature silicone and
screws may be used instead of gear clamps at connections of liner
to inlet and vent collars.
9) Connect the 2nd liner to the intake collar, seal connection with high
temperature silicone. Secure with gear clamp or screws.
10) Align vent connector plate with guides on unit.
11) Slide unit into masonry opening, while ensuring that the slot at the
rear of the connector plate mates up with the hold down plate on
the unit.
12) Secure with screw.
FLUE LINER
INSTALLATION
1) Cut the flex liner as required.
2) Mark the end of one liner with an "E" to indicate exhaust.
3) Connect the other end of the above liner to the exhaust side of the
termination cap, seal connection with high temperature silicone.
Secure with gear clamp or screws.
4) Connect the 2nd liner to the inlet side of the cap, seal connection
with high temperature silicone. Secure with gear clamp or screws.
Summary of Contents for L234-LP10
Page 37: ...Liberty L234 10 Direct Vent Gas Insert 37 37 warranty MAIN ASSEMBLY a ...
Page 38: ...38 Liberty L234 10 Direct Vent Gas Insert 38 parts list 537 924 Low Profile Faceplate ...
Page 39: ...Liberty L234 10 Direct Vent Gas Insert 39 39 notes ...
Page 44: ...44 Liberty L234 10 Direct Vent Gas Insert 44 warranty ...
Page 45: ...Liberty L234 10 Direct Vent Gas Insert 45 45 notes ...
Page 46: ...46 Liberty L234 10 Direct Vent Gas Insert 46 notes ...
Page 47: ......