Page 1: ...AS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas sup...

Page 2: ... of a fireplace at the flick of a switch The L234 NG10 and L234 LP10 have been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace Liberty...

Page 3: ...m NG to LP 17 Optional Brick Panel Installation 18 Safety screen install 19 Glass door removal install 19 Log Set Installation 20 Low profile faceplate Installation 24 Hearth trim Installation 25 Wiring Diagrams 26 Optional Wall Thermostat 27 Final Check 27 DC Spark Igniter 27 Battery Installation 27 First Fire 28 Operating Instructions Operating Instructions 28 Lighting Procedure 28 Shutdown Proc...

Page 4: ...l on the unit and if there is a difference the label on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts FortheStateofMassachusetts flexiblecon nectors shall not exceed 36 inches in length For the State of Massachusetts the appli ances individual manual shut off must be a t handle...

Page 5: ...ectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspec...

Page 6: ...234 10 Direct Vent Gas Insert 6 dimensions Shown with Low Profile Faceplate ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Page 7: ... SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS A PHYSICALBARRIERSISRECOMMEND ED IFTHERE ARE AT RISK INDIVIDUAL INTHE HOUSE TO RESTRICT ACCESS TO A FIREPLACE OR STOVE INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS YOUNG CHILDREN ANDOTHERATRISKINDIVIDUALSOUT OF THE ROOM AND AWAY FR...

Page 8: ...tion and repair should be done by a qualified service person 3 The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting beddingmaterial animalhair etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean 4 See general co...

Page 9: ...replace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all originalpartshavebeenreplaced andthefireplace re approved by the authority having jurisdiction FACTORY BUILT METAL WOOD BURNING FIREPLACE REQUIREMENTS NOTE Anypartsthatareremovedmustberemoved in a way that would allow them to be re installed if the insert is ever remove...

Page 10: ...s could contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm 8 Test gas pressure refer to the Gas Pipe Pressure Testing section Check aeration system refer to Gas Insert Aeration Systems section 9 Installstandardandoptionalfeatures Refer to the following sections where applicable a Brick Panels b Log Installation c Faceplate d Optional Hearth ...

Page 11: ...e mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour Unless otherwise stated the clearances listed below are Minimum distances to combustible materials Please Note A major cause of chimney related fires is due to a failure to maintain required clearances air space to combustible materials It is of t...

Page 12: ...et air collar of the termination cap NOTE Simpson Duravent can only be used with 3 liners INSTALLATION WITH 3 3 LINERS Part Description 948 305 3 Flex 35 ft intake exhaust 946 529 Regency Co linear DV Vertical Termination Cap Flashing The L234 is also approved for use with a 2 liner for air intake and a 3 liner for exhaust This would be suitable for a Class A wood burning chimney with a minimum 6 ...

Page 13: ...move the 4 screws that hold the vent restrictor plate in place 2 Remove the 3 collar from the top plate by undoing the 4 screws NOTE The screws are secured from the underside of the top plate Underside of Top Plate 3 Secure the 2 collar to the top plate using 4 screws in place of the 3 collar 4 Re install the top plate to the unit Top Plate with 2 Collar shown on Unit 4 Adjust the vent restrictor ...

Page 14: ...t collar of the vent connector plate marked with an E seal connection with high temperature silicone Secure with gear clamp or screws NOTES 1 Final gas connection should be made after unit is in place to avoid damage to the liner when pushing the unit into position 2 Mill pac may be used instead of high temperature silicone and screws may be used instead of gear clamps at connections of liner to i...

Page 15: ...NG 1 8 LP 1 8 Note Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty Note Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service 1 Remove the outer faceplate 2 Remove the safety screen 3 Remove the glass door a Pull the spring hook on the left that holds the door in place...

Page 16: ... 1 Make sure the valve is in the OFF position 2 Loosenthe IN and or OUT pressuretap s turningcounterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Light the pilot and turn the valve to ON position 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety ...

Page 17: ...ce with a 1 2 wrench and discard 9 Install the new LP burner orifice stamped 54 and tighten 10 Pull off the pilot cap to expose the pilot orifice 11 Unscrew the pilot orifice with the supplied allen key and replace it with the LP pilot orifice in the kit and re install the pilot cap 12 Remove the pilot on off extension knob by pulling the knob towards you Remove NG stepper motor by removing 3 screws in ...

Page 18: ...p them 2 Insert the back brick panel by carefully placing it against the back wall of the firebox and rest it on the rear log tray Back Brick Panel Rear Log Tray 3 Slide the right side brick panel into position and secure in place using the brick clip Repeat for left side Brick Clip Right Side Brick Panel Completed Brick Panel Installation NOTE Brick Panels are mandatory when using Optional Remote...

Page 19: ... on right side b Swing the door out 45 degrees and lift up and out Spring Hook Tab on screen assembly Folded Tab on screen assembly Tab on glass door Tab on glass door 1 Slide the folded tab on the screen assembly over the tab on the glass door left and right sides 2 Install screen assembly and glass door together and secure with spring hooks on left and right side To remove see Glass Door Removal...

Page 20: ... 711 2 714 2 711 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Fit log 2 711 into the pins on the rear log tray 2 711 3 Place log 2 714 on the base of the firebox in front of the burner 2 714 4 Fit log 2 712 into the pins on the middle of the burner 2 712 Read the instructions below carefully and refer to the images Dang...

Page 21: ... left side of log 2 713 into the pin on log 2 714 and rest the right side of the log on the burner plate pushing it against the tab 2 712 2 713 2 714 2 713 6 Place log 2 715 into the pin on log 2 712 and rest the right end of the log on the notch in log 2 713 2 715 2 712 Notch 2 713 2 712 Tab ...

Page 22: ...lace embers on the right side of the burner as shown 8 Fit log 2 716 into the pin on log 2 712 Right side of Burner 2 713 2 716 2 712 Also place a few embers along the burner tube next to log 2 713 Separate platinum embers and place on and around the embers Avoid stacking platinum embers ...

Page 23: ...Liberty L234 10 Direct Vent Gas Insert 23 23 installation 918 674a 01 03 08 4 L234 Completed Log Set Installation 2 711 2 716 2 715 2 712 2 713 2 714 ...

Page 24: ...ceplate backing and spacer to unit together as shown in Step 2 3 Install the receiver into the bracket located on the left side of the backing plate The receiver is pre wired to the appliance Tuck all wires into bracket See wiring diagram for details 5 Install the outer faceplate by hooking on to the brackets on the face plate backing 6 To remove reverse steps Tab on screen assembly Tab on glass d...

Page 25: ...e NOTE The tab bends at the back of the top piece of the hearth trim should be used as the measuring point to the hearth to measure the height required c Reattach the top piece of the hearth trim to the cut bottom piece by fitting in place Customize Hearth Trim Hearth Trim Installation Completed Hearth Trim Installation Diagram 1 2 Attachthesuppliedbracketstothetopofthehearthtrimwith2screws Note o...

Page 26: ...g for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation ENGLISH REMOTE TP TH TPTH Green White Red Black 9 Ground Neutral Live Red Minimum Convection A...

Page 27: ...ngtheappliancetoensurethecorrect firing rate noted on label at 15 minutes 2 Ifrequired adjustingtheprimaryairtoensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize 3 Check for proper draft CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer CAUTION Do ...

Page 28: ...button on the remote handheld transmitter An audible beep should be heard from the receiver ON OFF Button 6 The unit will turn on SHUTDOWN PROCEDURE 1 Press OFF ontheremoteorslidereceiverswitch from remote to OFF 2 Turn the gas control knob to the OFF position to turn off the pilot Pilot may be shut off during prolonged non use periods to conserve fuel Diagram 2 Remote shown in Manual Mode on Hi D...

Page 29: ...é et remplacez tout élément du système de contrôle ou de commande qui a été plongé dans l eau DO NOT REMOVE THIS INSTRUCTION PLATE TO TURN OFF GAS APPLIANCE This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 CAUTION Hot while in operation Do not touch Severe Bu...

Page 30: ... APPLIANCE CAUTION ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE MAINTENANCE INSTRUCTIONS 1 Always turn the gas valve to the off position before cleaning For relighting refer to lighting instructions Keep the burner and controlcompartmentcleanbybrushi...

Page 31: ...brick panels if installed 7 Remove the burner by undoing the 3 screws 8 Remove the burner tray by undoing the 4 screws Burner Removed Burner Tray Removed 9 Remove the rear log tray by undoing the 3 screws Rear Log Tray Removed 4 Remove the glass door a Pull the spring hook on the left that holds the door in place Place the hook into the opening towards the outside of the bracket Repeat on right si...

Page 32: ... the fan by sliding the fan forward and lift up and out 14 Remove the ground screw which holds the ground wire Ground Wire 15 Replace the fan NOTE Bendtheconnectorclipsdownbefore re installing the fan cover plate Connector Clips 16 Reverse steps 14 1 10 Remove the fan cover plate by undoing the 12 screws that hold it in place Fan Cover Plate Removed ...

Page 33: ...g towards the outside of the bracket Repeat on right side b Swing the door out 45 degrees and lift up and out 6 Disconnect the gas connection to the valve 7 Disconnect the ignitor wire from the DC Sparker 8 Disconnect the valve wires from the DC Sparker 9 Unplug the 2 connectors from the valve DC Sparker Wires 3 Remove the logs 4 Remove brick panels if installed 5 Remove the valve shield by undoin...

Page 34: ... screws Rear Log Tray Removed 13 Remove the 12 screws that hold the valve tray to the firebox and carefully pull out 14 Replace the valve 15 Reverse steps 13 1 10 Remove the burner by undoing the 3 screws 11 Remove the burner tray by undoing the 4 screws Burner Removed Burner Tray Removed Valve Removed ...

Page 35: ... list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should ...

Page 36: ...t 14 536 091 Pilot Shield 15 910 038 P Pilot Assy 3 Flame S I T NG 910 039 P Pilot Assy 3 Flame S I T LP 904 430 Orifice 42 NG 904 163 Orifice 54 LP 936 170 Orifice Gasket Part Description 16 537 574 P Valve Assembly NG 537 576 P Valve Assembly LP 910 073 Battery Holder DC Sparker 910 074 DC Sparker Switch 910 578 Valve S I T Natural Gas 910 580 Valve S I T Propane 18 535 001 Safety Screen Frame 1...

Page 37: ...Liberty L234 10 Direct Vent Gas Insert 37 37 warranty MAIN ASSEMBLY a ...

Page 38: ...38 Liberty L234 10 Direct Vent Gas Insert 38 parts list 537 924 Low Profile Faceplate ...

Page 39: ...Liberty L234 10 Direct Vent Gas Insert 39 39 notes ...

Page 40: ...trol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assem...

Page 41: ...fts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appl...

Page 42: ...he U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a bri...

Page 43: ... in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases m...

Page 44: ...44 Liberty L234 10 Direct Vent Gas Insert 44 warranty ...

Page 45: ...Liberty L234 10 Direct Vent Gas Insert 45 45 notes ...

Page 46: ...46 Liberty L234 10 Direct Vent Gas Insert 46 notes ...

Page 47: ......

Page 48: ...ler Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial ___________________________________________________...

Reviews: